Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

How to Evaluate Appendices with Borderline Diameters on CT: Proposal of a Quick Solution to Overcome the Limitations of the Established CT Criteria

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Min Yeong-
dc.contributor.authorKim, Yongsoo-
dc.contributor.authorRyu, Jeong Ah-
dc.contributor.authorKim, Tae Yeop-
dc.date.accessioned2022-07-16T01:47:25Z-
dc.date.available2022-07-16T01:47:25Z-
dc.date.created2021-05-11-
dc.date.issued2014-12-
dc.identifier.issn1076-6332-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/158521-
dc.description.abstractRationale and Objectives: To propose a useful computed tomography (CT) criterion, the diameter with compression (DWC), especially in appendices with borderline diameters. Materials and MethodS: We retrospectively collected 216 patients with visible appendices on CT after clinicopathologic confirmation of appendicitis. Each CT criterion of appendicitis was evaluated by an experienced abdominal radiologist: maximal outer diameter (MOD), DWC, mural thickness and enhancement, periappendiceal infiltration, and appendicolith. DWC is the expected diameter after deduction of the intraluminal compressible contents such as air and feces. All the CT criteria were compared in the appendicitis and nonappendicitis group. Results: The areas under the receiver operating characteristic curve (AUC) of the MOD and the DWC were 0.967 and 0.973, respectively. The optimal cutoff value was 8.2 mm for the MOD and 6.6 mm for the DWC. Twenty-five of the 80 appendicitis patients (31.2%) and 62 of the 136 nonappendicitis patients (45.6%) had MODs between 5.7 mm and 9.8 mm in the overlap between the two groups. In this overlap, the AUC of the MODs declined sharply to 0.767, whereas the AUC of the DWCs remained 0.923. Use of the criterion of DWC >6.6 mm yielded a sensitivity of 84.0%, a specificity of 88.7%, and an accuracy of 87.4%. There were no other criteria with both sensitivity and specificity >80% in the range of overlap. Conclusions: The proposed CT criterion of the DWC is not affected by normal distension or periappendiceal inflammation but only by true appendicitis. Therefore, DWC can improve the diagnostic performance of appendicitis regardless of the MOD.-
dc.language영어-
dc.language.isoen-
dc.publisherELSEVIER SCIENCE INC-
dc.titleHow to Evaluate Appendices with Borderline Diameters on CT: Proposal of a Quick Solution to Overcome the Limitations of the Established CT Criteria-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Yongsoo-
dc.contributor.affiliatedAuthorRyu, Jeong Ah-
dc.identifier.doi10.1016/j.acra.2014.07.005-
dc.identifier.scopusid2-s2.0-84908567211-
dc.identifier.wosid000344844400012-
dc.identifier.bibliographicCitationACADEMIC RADIOLOGY, v.21, no.12, pp.1573 - 1578-
dc.relation.isPartOfACADEMIC RADIOLOGY-
dc.citation.titleACADEMIC RADIOLOGY-
dc.citation.volume21-
dc.citation.number12-
dc.citation.startPage1573-
dc.citation.endPage1578-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordPlusCOMPUTED-TOMOGRAPHY-
dc.subject.keywordPlusACUTE APPENDICITIS-
dc.subject.keywordPlusMAXIMUM DEPTH-
dc.subject.keywordPlusABDOMINAL-PAIN-
dc.subject.keywordPlusROW CT-
dc.subject.keywordPlusFLUID-
dc.subject.keywordPlusVISUALIZATION-
dc.subject.keywordPlusTHICKNESS-
dc.subject.keywordPlusDIAGNOSIS-
dc.subject.keywordPlusFEATURES-
dc.subject.keywordAuthorAppendix-
dc.subject.keywordAuthorappendicitis-
dc.subject.keywordAuthorCT-
dc.subject.keywordAuthordiameter-
dc.identifier.urlhttps://www.clinicalkey.com/#!/content/playContent/1-s2.0-S1076633214002670?returnurl=https:%2F%2Flinkinghub.elsevier.com%2Fretrieve%2Fpii%2FS1076633214002670%3Fshowall%3Dtrue&referrer=-
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 영상의학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Ryu, Jeong Ah photo

Ryu, Jeong Ah
COLLEGE OF MEDICINE (DEPARTMENT OF RADIOLOGY)
Read more

Altmetrics

Total Views & Downloads

BROWSE