컨테인먼트가 적용된 모듈러 데이터센터의 공조 팬 제어 방안에 관한 실험적 연구
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 함상우 | - |
dc.contributor.author | 김민휘 | - |
dc.contributor.author | 윤동섭 | - |
dc.contributor.author | 정재원 | - |
dc.date.accessioned | 2022-07-16T02:19:09Z | - |
dc.date.available | 2022-07-16T02:19:09Z | - |
dc.date.created | 2021-05-13 | - |
dc.date.issued | 2014-10 | - |
dc.identifier.issn | 2287-5786 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/158805 | - |
dc.description.abstract | The purpose of this study is to experimentally demonstrate the fan control strategy of computer room air handler (CRAH) in amodular data center with containment architecture. In containment architecture, variable speed drive fan is widely accepted in orderto reduce fan energy. However, the selection of inappropriate control variable for fan speed yields improper operation of fan; fanairflow does not change when the IT equipment is in part-load operation. In this study, fan control strategy that modulates fanspeed according to the differential pressure between cold- and hot-aisle through containment is experimented. As a result, thisstrategy reduces the discrepancy between rack and CRAH fan airflow though small recirculation is occurred due to gap betweenfloor and racks. | - |
dc.language | 한국어 | - |
dc.language.iso | ko | - |
dc.publisher | 대한건축학회 | - |
dc.title | 컨테인먼트가 적용된 모듈러 데이터센터의 공조 팬 제어 방안에 관한 실험적 연구 | - |
dc.title.alternative | An experimental study on the fan control of computer room air handler in a modular data center with cold-aisle containment | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | 정재원 | - |
dc.identifier.bibliographicCitation | 대한건축학회 추계학술발표대회논문집, v.34, no.2, pp.285 - 286 | - |
dc.relation.isPartOf | 대한건축학회 추계학술발표대회논문집 | - |
dc.citation.title | 대한건축학회 추계학술발표대회논문집 | - |
dc.citation.volume | 34 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 285 | - |
dc.citation.endPage | 286 | - |
dc.type.rims | ART | - |
dc.type.docType | Proceeding | - |
dc.description.journalClass | 2 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | other | - |
dc.subject.keywordAuthor | 모듈러 데이터센터 | - |
dc.subject.keywordAuthor | 공조 팬 제어 | - |
dc.subject.keywordAuthor | 컨테인먼트 | - |
dc.subject.keywordAuthor | Modular Data Center | - |
dc.subject.keywordAuthor | CRAH Fan Control | - |
dc.subject.keywordAuthor | Containment | - |
dc.identifier.url | https://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE02484987 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1365
COPYRIGHT © 2021 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.