기밀성능 예측모델 보정에 따른 탑상형 공동주택의 수직 압력분포예측결과 개선에 관한 연구
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 한슬기 | - |
dc.contributor.author | 이은지 | - |
dc.contributor.author | 조수영 | - |
dc.contributor.author | 정재원 | - |
dc.date.accessioned | 2022-07-16T02:36:20Z | - |
dc.date.available | 2022-07-16T02:36:20Z | - |
dc.date.created | 2021-05-13 | - |
dc.date.issued | 2014-10 | - |
dc.identifier.issn | 1976-6483 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/158920 | - |
dc.description.abstract | The objective of this research is to verify the tuning process which is predict a pressure distribution in tower-type apartment buildingby simulation. It is evaluated that how accurate each model’s results compared with measurement of indoor pressure. Study in advance,the tuning process of building simulation is designed to predict air-tightness and the tuning precess show that it has validity. Therefore,whether the tuning process is valid or not is evaluated to predict stack effect in high-rise building. As a preliminary step, a high-risebuilding was selected and the pressure of elevator zone and stair hall was measurement on every floor to confirm the accuracy of simulationresults. Also, the air leakage of building element was measured to enter into the model to tune. At first, the data of intial model isnot adjusted. At next step, the model is tuned by replacing initial data obtained literature with experimental date. With each step ofthe tuning process, the simulation results are verified. The results show that the indoor pressure on each floor in simulation is similarto that of actual test. | - |
dc.language | 한국어 | - |
dc.language.iso | ko | - |
dc.publisher | 한국건축친환경설비학회 | - |
dc.title | 기밀성능 예측모델 보정에 따른 탑상형 공동주택의 수직 압력분포예측결과 개선에 관한 연구 | - |
dc.title.alternative | Improvement of Vertical Pressure Distribution Prediction by tuning the Airtightness Model in Tower-type Apartment Buildings | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | 정재원 | - |
dc.identifier.bibliographicCitation | 한국건축친환경설비학회 논문집, v.8, no.5, pp.244 - 251 | - |
dc.relation.isPartOf | 한국건축친환경설비학회 논문집 | - |
dc.citation.title | 한국건축친환경설비학회 논문집 | - |
dc.citation.volume | 8 | - |
dc.citation.number | 5 | - |
dc.citation.startPage | 244 | - |
dc.citation.endPage | 251 | - |
dc.type.rims | ART | - |
dc.identifier.kciid | ART001927139 | - |
dc.description.journalClass | 2 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | kci | - |
dc.description.journalRegisteredClass | other | - |
dc.subject.keywordAuthor | Multi-zone network modeling | - |
dc.subject.keywordAuthor | Tuning process | - |
dc.subject.keywordAuthor | Stack effect | - |
dc.subject.keywordAuthor | Building pressure | - |
dc.subject.keywordAuthor | 멀티존 네트워크 모델링 | - |
dc.subject.keywordAuthor | 모델 보정 프로세스 | - |
dc.subject.keywordAuthor | 연돌 현상 | - |
dc.subject.keywordAuthor | 건물 실내 압력 | - |
dc.identifier.url | https://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE02512147&language=ko_KR&hasTopBanner=false | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1365
COPYRIGHT © 2021 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.