Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Vital sign monitoring of a non-stationary human through IR-UWB radar

Full metadata record
DC Field Value Language
dc.contributor.authorKhan, Faheem-
dc.contributor.authorChoi, Jeong Woo-
dc.contributor.authorCho, Sung Ho-
dc.date.accessioned2022-07-16T03:06:15Z-
dc.date.available2022-07-16T03:06:15Z-
dc.date.created2021-05-13-
dc.date.issued2014-09-
dc.identifier.issn0000-0000-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/159188-
dc.description.abstractIn this paper the vital sign monitoring of a non-stationary human are measured by combining vital sign monitoring algorithm with movement detection method. First respiration and heart beat rate for a stationary human are explained and then a method for movement detection is discussed. The movement detection method is based on the autocorrelation property of a signal. Once the movement is detected then the most recent measurement value (before the movement is detected) is considered as the measurements throughout the motion period. And then the measurement process is restored when object comes back to stationary state. Experimental results are given to prove the stability of the algorithm.-
dc.language영어-
dc.language.isoen-
dc.publisherInstitute of Electrical and Electronics Engineers Inc.-
dc.titleVital sign monitoring of a non-stationary human through IR-UWB radar-
dc.typeArticle-
dc.contributor.affiliatedAuthorCho, Sung Ho-
dc.identifier.doi10.1109/ICNIDC.2014.7000357-
dc.identifier.scopusid2-s2.0-84929417764-
dc.identifier.bibliographicCitationProceedings of 2014 4th IEEE International Conference on Network Infrastructure and Digital Content, IEEE IC-NIDC 2014, pp.511 - 514-
dc.relation.isPartOfProceedings of 2014 4th IEEE International Conference on Network Infrastructure and Digital Content, IEEE IC-NIDC 2014-
dc.citation.titleProceedings of 2014 4th IEEE International Conference on Network Infrastructure and Digital Content, IEEE IC-NIDC 2014-
dc.citation.startPage511-
dc.citation.endPage514-
dc.type.rimsART-
dc.type.docTypeConference Paper-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscopus-
dc.subject.keywordPlusAutocorrelation-
dc.subject.keywordPlusUltra-wideband (UWB)-
dc.subject.keywordPlusheartbeat frequency-
dc.subject.keywordPlusMovement detection-
dc.subject.keywordPlusNonstationary-
dc.subject.keywordPlusRespiration rate-
dc.subject.keywordPlusVital sign-
dc.subject.keywordPlusCorrelation detectors-
dc.subject.keywordAuthorautocorrelation-
dc.subject.keywordAuthorheartbeat frequency-
dc.subject.keywordAuthormovement detection-
dc.subject.keywordAuthornon-stationary-
dc.subject.keywordAuthorrespiration rate-
dc.subject.keywordAuthorvital signs-
dc.identifier.urlhttps://ieeexplore.ieee.org/document/7000357/-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 융합전자공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Cho, Sung Ho photo

Cho, Sung Ho
COLLEGE OF ENGINEERING (SCHOOL OF ELECTRONIC ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE