Single Walled Carbon Nanotube-Based Junction Biosensor for Detection of Escherichia coli
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Yamada, Kara | - |
dc.contributor.author | Kim, Chong-Tai | - |
dc.contributor.author | Kim, Jong-Hoon | - |
dc.contributor.author | Chung, Jae-Hyun | - |
dc.contributor.author | Lee, Hyeon Gyu | - |
dc.contributor.author | Jun, Soojin | - |
dc.date.accessioned | 2022-07-16T03:27:41Z | - |
dc.date.available | 2022-07-16T03:27:41Z | - |
dc.date.created | 2021-05-12 | - |
dc.date.issued | 2014-09 | - |
dc.identifier.issn | 1932-6203 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/159259 | - |
dc.description.abstract | Foodborne pathogen detection using biomolecules and nanomaterials may lead to platforms for rapid and simple electronic biosensing. Integration of single walled carbon nanotubes (SWCNTs) and immobilized antibodies into a disposable bio-nano combinatorial junction sensor was fabricated for detection of Escherichia coli K-12. Gold tungsten wires (50 mm diameter) coated with polyethylenimine (PEI) and SWCNTs were aligned to form a crossbar junction, which was functionalized with streptavidin and biotinylated antibodies to allow for enhanced specificity towards targeted microbes. In this study, changes in electrical current (Delta I) after bioaffinity reactions between bacterial cells (E. coli K-12) and antibodies on the SWCNT surface were monitored to evaluate the sensor's performance. The averaged Delta I increased from 33.13 nA to 290.9 nA with the presence of SWCNTs in a 10(8) CFU/mL concentration of E. coli, thus showing an improvement in sensing magnitude. Electrical current measurements demonstrated a linear relationship (R-2 = 0.973) between the changes in current and concentrations of bacterial suspension in range of 10(2)-10(5) CFU/mL. Current decreased as cell concentrations increased, due to increased bacterial resistance on the bio-nano modified surface. The detection limit of the developed sensor was 10(2) CFU/mL with a detection time of less than 5 min with nanotubes. Therefore, the fabricated disposable junction biosensor with a functionalized SWCNT platform shows potential for high-performance biosensing and application as a detection device for foodborne pathogens. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | PUBLIC LIBRARY SCIENCE | - |
dc.title | Single Walled Carbon Nanotube-Based Junction Biosensor for Detection of Escherichia coli | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lee, Hyeon Gyu | - |
dc.identifier.doi | 10.1371/journal.pone.0105767 | - |
dc.identifier.scopusid | 2-s2.0-84907192240 | - |
dc.identifier.wosid | 000342921200006 | - |
dc.identifier.bibliographicCitation | PLOS ONE, v.9, no.9, pp.1 - 7 | - |
dc.relation.isPartOf | PLOS ONE | - |
dc.citation.title | PLOS ONE | - |
dc.citation.volume | 9 | - |
dc.citation.number | 9 | - |
dc.citation.startPage | 1 | - |
dc.citation.endPage | 7 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | Y | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Science & Technology - Other Topics | - |
dc.relation.journalWebOfScienceCategory | Multidisciplinary Sciences | - |
dc.subject.keywordPlus | MICROWIRE SENSOR | - |
dc.subject.keywordPlus | RAPID DETECTION | - |
dc.subject.keywordPlus | IMMUNOSENSOR | - |
dc.subject.keywordPlus | ADSORPTION | - |
dc.subject.keywordPlus | TOOLS | - |
dc.subject.keywordPlus | FOOD | - |
dc.identifier.url | https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0105767 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1365
COPYRIGHT © 2021 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.