Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

A thin film polyimide mesh microelectrode for chronic epidural electrocorticography recording with enhanced contactability

Full metadata record
DC Field Value Language
dc.contributor.authorBaek, Dong-Hyun-
dc.contributor.authorLee, Jeyeon-
dc.contributor.authorByeon, Hang Jin-
dc.contributor.authorChoi, Hoseok-
dc.contributor.authorKim, In Young-
dc.contributor.authorLee, Kyoung-Min-
dc.contributor.authorPak, James Jungho-
dc.contributor.authorJang, Dong Pyo-
dc.contributor.authorLee, Sang-Hoon-
dc.date.accessioned2022-07-16T03:38:50Z-
dc.date.available2022-07-16T03:38:50Z-
dc.date.created2021-05-12-
dc.date.issued2014-08-
dc.identifier.issn1741-2560-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/159390-
dc.description.abstractObjective. Epidural electrocorticography (ECoG) activity may be more reliable and stable than single-unit-activity or local field potential. Invasive brain computer interface (BCI) devices are limited by mechanical mismatching and cellular reactive responses due to differences in the elastic modulus and the motion of stiff electrodes. We propose a mesh-shaped electrode to enhance the contactability between surface of dura and electrode. Approach. We designed a polyimide ( PI) electrode with a mesh pattern for more conformal contact with a curved surface. We compared the contact capability of mesh PI electrodes with conventionally used sheet PI electrode. The electrical properties of the mesh PI electrode were evaluated for four weeks. We recorded the epidural ECoG (eECoG) activity on the surface of rhesus monkey brains while they performed a saccadic task for four months. Main results. The mesh PI electrode showed good contact with the agarose brain surface, as evaluated by visual inspection and signal measurement. It was about 87% accurate in predicting the direction of saccade eye movement. Significance. Our results indicate that the mesh PI electrode was flexible and good contact on the curved surface and can record eECoG activity maintaining close contact to dura, which was proved by in vivo and in vitro test.-
dc.language영어-
dc.language.isoen-
dc.publisherIOP PUBLISHING LTD-
dc.titleA thin film polyimide mesh microelectrode for chronic epidural electrocorticography recording with enhanced contactability-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, In Young-
dc.contributor.affiliatedAuthorJang, Dong Pyo-
dc.identifier.doi10.1088/1741-2560/11/4/046023-
dc.identifier.scopusid2-s2.0-84904652411-
dc.identifier.wosid000340046500023-
dc.identifier.bibliographicCitationJOURNAL OF NEURAL ENGINEERING, v.11, no.4, pp.1 - 10-
dc.relation.isPartOfJOURNAL OF NEURAL ENGINEERING-
dc.citation.titleJOURNAL OF NEURAL ENGINEERING-
dc.citation.volume11-
dc.citation.number4-
dc.citation.startPage1-
dc.citation.endPage10-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaNeurosciences & Neurology-
dc.relation.journalWebOfScienceCategoryEngineering, Biomedical-
dc.relation.journalWebOfScienceCategoryNeurosciences-
dc.subject.keywordPlusBRAIN-COMPUTER INTERFACES-
dc.subject.keywordPlusCOMPLICATIONS-
dc.subject.keywordPlusPOTENTIALS-
dc.subject.keywordAuthorepidural ECoG-
dc.subject.keywordAuthorneural prosthetics-
dc.subject.keywordAuthorbrain-computer interface-
dc.identifier.urlhttps://iopscience.iop.org/article/10.1088/1741-2560/11/4/046023-
Files in This Item
Go to Link
Appears in
Collections
서울 의생명공학전문대학원 > 서울 의생명공학전문대학원 > 1. Journal Articles
서울 의과대학 > 서울 의공학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, In Young photo

Kim, In Young
COLLEGE OF MEDICINE (DEPARTMENT OF BIOMEDICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE