Particle Deposition Velocity Onto EUVL Masks in Vertical Airflow
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Won-Geun | - |
dc.contributor.author | Lee, Handol | - |
dc.contributor.author | Yook, Se-Jin | - |
dc.contributor.author | Lee, Kwan-Soo | - |
dc.date.accessioned | 2022-07-16T03:41:25Z | - |
dc.date.available | 2022-07-16T03:41:25Z | - |
dc.date.created | 2021-05-12 | - |
dc.date.issued | 2014-08 | - |
dc.identifier.issn | 0894-6507 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/159420 | - |
dc.description.abstract | Extreme ultraviolet lithography (EUVL) masks are vulnerable to particulate contamination due to the unavailability of pellicles. Particle deposition velocity is used to assess the level of particulate contamination. The particle deposition velocity onto a circular disk or a square flat plate situated perpendicular to the airflow was investigated. The numerical and experimental methods employed in this paper were validated by comparing the numerically simulated mean Sherwood numbers or the experimentally determined particle deposition velocities with the theoretically predicted values for the circular disk, representing a wafer, exposed to vertical airflow. Then, an equation for predicting the particle deposition velocity onto a square flat plate, simulating a EUVL mask, in vertical airflow was suggested by numerically obtaining the mean Sherwood number correlation, and validated through experiments. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC | - |
dc.title | Particle Deposition Velocity Onto EUVL Masks in Vertical Airflow | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Yook, Se-Jin | - |
dc.identifier.doi | 10.1109/TSM.2014.2337374 | - |
dc.identifier.scopusid | 2-s2.0-84905818418 | - |
dc.identifier.wosid | 000340627300014 | - |
dc.identifier.bibliographicCitation | IEEE TRANSACTIONS ON SEMICONDUCTOR MANUFACTURING, v.27, no.3, pp.417 - 421 | - |
dc.relation.isPartOf | IEEE TRANSACTIONS ON SEMICONDUCTOR MANUFACTURING | - |
dc.citation.title | IEEE TRANSACTIONS ON SEMICONDUCTOR MANUFACTURING | - |
dc.citation.volume | 27 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 417 | - |
dc.citation.endPage | 421 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Physics | - |
dc.relation.journalWebOfScienceCategory | Engineering, Manufacturing | - |
dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
dc.relation.journalWebOfScienceCategory | Physics, Applied | - |
dc.relation.journalWebOfScienceCategory | Physics, Condensed Matter | - |
dc.subject.keywordPlus | INVERTED FLAT SURFACE | - |
dc.subject.keywordPlus | HEAT-TRANSFER | - |
dc.subject.keywordPlus | SIMULTANEOUS ELECTROPHORESIS | - |
dc.subject.keywordPlus | PARTICULATE CONTAMINATION | - |
dc.subject.keywordPlus | SEMICONDUCTOR WAFERS | - |
dc.subject.keywordPlus | FLUID-FLOW | - |
dc.subject.keywordPlus | THERMOPHORESIS | - |
dc.subject.keywordPlus | PLATE | - |
dc.subject.keywordPlus | PROTECTION | - |
dc.subject.keywordAuthor | Deposition velocity | - |
dc.subject.keywordAuthor | wafer | - |
dc.subject.keywordAuthor | mask | - |
dc.subject.keywordAuthor | EUVL | - |
dc.subject.keywordAuthor | particle contamination | - |
dc.identifier.url | https://ieeexplore.ieee.org/document/6851191 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1365
COPYRIGHT © 2021 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.