Design issues in vital sign monitoring through IR UWB radar
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Khan, Faheem | - |
dc.contributor.author | Choi, Jeong Woo | - |
dc.contributor.author | Cho, Sung Ho | - |
dc.date.accessioned | 2022-07-16T04:28:34Z | - |
dc.date.available | 2022-07-16T04:28:34Z | - |
dc.date.created | 2021-05-13 | - |
dc.date.issued | 2014-06 | - |
dc.identifier.issn | 0000-0000 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/159809 | - |
dc.description.abstract | Measurement of respiration and heartbeat rate through IR UWB radar has been discussed; the main issues related to the extraction of heartbeat signal from the received signal are also described. An algorithm for estimation of heartbeat frequency from the received signal has been proposed. A notch filter bank is used to find the maximum peak frequencies in the observation frequency range of about 1Hz to 3 Hz. The heart rate may be estimated even if its magnitude is not the maximum in the specified range of frequencies. The main contribution of this paper is to differentiate the heart rate from the closely located respiration harmonics by adjusting the frequency resolution and notch filter bandwidth. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | Institute of Electrical and Electronics Engineers Inc. | - |
dc.title | Design issues in vital sign monitoring through IR UWB radar | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Cho, Sung Ho | - |
dc.identifier.doi | 10.1109/ISCE.2014.6884515 | - |
dc.identifier.scopusid | 2-s2.0-84907419441 | - |
dc.identifier.bibliographicCitation | Proceedings of the International Symposium on Consumer Electronics, ISCE, pp.1 - 2 | - |
dc.relation.isPartOf | Proceedings of the International Symposium on Consumer Electronics, ISCE | - |
dc.citation.title | Proceedings of the International Symposium on Consumer Electronics, ISCE | - |
dc.citation.startPage | 1 | - |
dc.citation.endPage | 2 | - |
dc.type.rims | ART | - |
dc.type.docType | Conference Paper | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scopus | - |
dc.subject.keywordPlus | Consumer electronics | - |
dc.subject.keywordPlus | Filter banks | - |
dc.subject.keywordPlus | Frequency estimation | - |
dc.subject.keywordPlus | Heart | - |
dc.subject.keywordPlus | Notch filters | - |
dc.subject.keywordPlus | Radar | - |
dc.subject.keywordPlus | Frequency resolutions | - |
dc.subject.keywordPlus | Harmonics | - |
dc.subject.keywordPlus | Heartbeat Frequency | - |
dc.subject.keywordPlus | Heartbeat signals | - |
dc.subject.keywordPlus | Observation frequencies | - |
dc.subject.keywordPlus | Respiration rate | - |
dc.subject.keywordPlus | Vital sign | - |
dc.subject.keywordPlus | Vital sign monitoring | - |
dc.subject.keywordPlus | Radar measurement | - |
dc.subject.keywordAuthor | Harmonics | - |
dc.subject.keywordAuthor | Heartbeat Frequency | - |
dc.subject.keywordAuthor | Notch Filter | - |
dc.subject.keywordAuthor | Respiration Rate | - |
dc.subject.keywordAuthor | Vital Signs | - |
dc.identifier.url | https://ieeexplore.ieee.org/document/6884515 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1365
COPYRIGHT © 2021 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.