Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Investigation of the effects of different types of interlayers on floor impact sound insulation in box-frame reinforced concrete structures

Full metadata record
DC Field Value Language
dc.contributor.authorYoo, Seung Yup-
dc.contributor.authorJeon, Jin Yong-
dc.date.accessioned2022-07-16T04:31:22Z-
dc.date.available2022-07-16T04:31:22Z-
dc.date.created2021-05-12-
dc.date.issued2014-06-
dc.identifier.issn0360-1323-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/159841-
dc.description.abstractIn the present study, the effects of resilient isolators and viscoelastic damping materials on reducing heavyweight floor impact sounds from reinforced concrete structures were investigated using FEM simulations and in situ measurements. At first, the dynamic properties of the materials were measured using a beam transfer function method to include the properties in an FEM simulation. As a result, the damping materials provided a higher loss factor and dynamic elastic modulus than the resilient isolators. Subsequently, FEM simulations and in situ measurements were conducted to investigate the effects of the interlayers on the characteristics of floor impact sounds and vibrations. The results indicated that the impact vibration acceleration level and floor impact sounds at low frequencies were significantly decreased owing to the installation of damping materials, whereas the impact sound pressure levels at low frequencies were increased as a result of the use of resilient isolators.-
dc.language영어-
dc.language.isoen-
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD-
dc.titleInvestigation of the effects of different types of interlayers on floor impact sound insulation in box-frame reinforced concrete structures-
dc.typeArticle-
dc.contributor.affiliatedAuthorJeon, Jin Yong-
dc.identifier.doi10.1016/j.buildenv.2014.03.008-
dc.identifier.scopusid2-s2.0-84897396089-
dc.identifier.wosid000336359500012-
dc.identifier.bibliographicCitationBUILDING AND ENVIRONMENT, v.76, pp.105 - 112-
dc.relation.isPartOfBUILDING AND ENVIRONMENT-
dc.citation.titleBUILDING AND ENVIRONMENT-
dc.citation.volume76-
dc.citation.startPage105-
dc.citation.endPage112-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaConstruction & Building Technology-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalWebOfScienceCategoryConstruction & Building Technology-
dc.relation.journalWebOfScienceCategoryEngineering, Environmental-
dc.relation.journalWebOfScienceCategoryEngineering, Civil-
dc.subject.keywordPlusFLOATING FLOOR-
dc.subject.keywordPlusNOISE-
dc.subject.keywordAuthorViscoelastic damping material-
dc.subject.keywordAuthorFloor impact sound-
dc.subject.keywordAuthorConstrained layer damping-
dc.subject.keywordAuthorFloating floor-
dc.identifier.urlhttps://www-sciencedirect-com-ssl.access.hanyang.ac.kr/science/article/pii/S0360132314000602-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 건축공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jeon, Jin Yong photo

Jeon, Jin Yong
COLLEGE OF ENGINEERING (SCHOOL OF ARCHITECTURAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE