Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Parametric response mapping of dynamic CT as an imaging biomarker to distinguish viability of hepatocellular carcinoma treated with transcatheter arterial chemoembolization

Full metadata record
DC Field Value Language
dc.contributor.authorChoi, Seung Joon-
dc.contributor.authorKim, Jonghoon-
dc.contributor.authorSeo, Jongbum-
dc.contributor.authorKim, Hyung Sik-
dc.contributor.authorLee, Jong-min-
dc.contributor.authorPark, Hyunjin-
dc.date.accessioned2022-07-16T04:31:57Z-
dc.date.available2022-07-16T04:31:57Z-
dc.date.issued2014-06-
dc.identifier.issn0942-8925-
dc.identifier.issn1432-0509-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/159848-
dc.description.abstractAccurate assessment of viability of hepatocellular carcinoma (HCC) after transcatheter arterial chemoembolization (TACE) is important for therapy planning. The purpose of this study is to determine the diagnostic value of a novel image analysis method called parametric response mapping (PRM) in predicting viability of tumor in HCC treated with TACE for dynamic CT images. 35 patients who had 35 iodized-oil defect areas (IODAs) in HCCs treated with TACE were included in our study. These patients were divided into two groups, one group with viable tumors (n = 22) and the other group with non-viable tumors (n = 13) in the IODA. All patients were followed up using triple-phase dynamic CT after the treatment. We compared (a) manual analysis, (b) using PRM results, and (c) using PRM results with automatic classifier to distinguish between two tumor groups based on dynamic CT images from two longitudinal exams. Two radiologists performed the manual analysis. The PRM approach was implemented using prototype software. We adopted an off-the-shelf k nearest neighbor (kNN) classifier and leave-one-out cross-validation for the third approach. The area under the curve (AUC) values were compared for three approaches. Manual analysis yielded AUC of 0.74, using PRM results yielded AUC of 0.84, and using PRM results with an automatic classifier yielded AUC of 0.87. We improved upon the standard manual analysis approach by adopting a novel image analysis method of PRM combined with an automatic classifier.-
dc.format.extent8-
dc.language영어-
dc.language.isoENG-
dc.publisherSpringer New York-
dc.titleParametric response mapping of dynamic CT as an imaging biomarker to distinguish viability of hepatocellular carcinoma treated with transcatheter arterial chemoembolization-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.1007/s00261-014-0087-z-
dc.identifier.scopusid2-s2.0-84903472542-
dc.identifier.wosid000337742200010-
dc.identifier.bibliographicCitationAbdominal Imaging, v.39, no.3, pp 518 - 525-
dc.citation.titleAbdominal Imaging-
dc.citation.volume39-
dc.citation.number3-
dc.citation.startPage518-
dc.citation.endPage525-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasssci-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaGastroenterology & Hepatology-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryGastroenterology & Hepatology-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordPlusTRANSARTERIAL CHEMOEMBOLIZATION-
dc.subject.keywordPlusLIPIODOL-CHEMOEMBOLIZATION-
dc.subject.keywordPlusEMBOLIZATION-
dc.subject.keywordPlusTHERAPY-
dc.subject.keywordPlusMAP-
dc.subject.keywordPlusLIVER-
dc.subject.keywordPlusRECURRENCES-
dc.subject.keywordPlusCOMBINATION-
dc.subject.keywordPlusMANAGEMENT-
dc.subject.keywordPlusSORAFENIB-
dc.subject.keywordAuthorHepatocellular carcinoma-
dc.subject.keywordAuthorParametric response mapping-
dc.subject.keywordAuthorAutomatic classifier-
dc.subject.keywordAuthorTranscatheter arterial chemoembolization-
dc.subject.keywordAuthorDynamic CT-
dc.subject.keywordAuthorLongitudinal exam-
dc.identifier.urlhttps://link.springer.com/article/10.1007%2Fs00261-014-0087-z-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Jong Min photo

Lee, Jong Min
COLLEGE OF ENGINEERING (서울 바이오메디컬공학전공)
Read more

Altmetrics

Total Views & Downloads

BROWSE