Cited 0 time in
Tetrahedral-mesh-based computational human phantom for fast Monte Carlo dose calculations
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Yeom, Yeon Soo | - |
| dc.contributor.author | Jeong, Jong Hwi | - |
| dc.contributor.author | Han, Min Cheol | - |
| dc.contributor.author | Kim, Chan Hyeong | - |
| dc.date.accessioned | 2022-07-16T04:33:37Z | - |
| dc.date.available | 2022-07-16T04:33:37Z | - |
| dc.date.issued | 2014-06 | - |
| dc.identifier.issn | 0031-9155 | - |
| dc.identifier.issn | 1361-6560 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/159869 | - |
| dc.description.abstract | Although polygonal-surface computational human phantoms can address several critical limitations of conventional voxel phantoms, their Monte Carlo simulation speeds are much slower than those of voxel phantoms. In this study, we sought to overcome this problem by developing a new type of computational human phantom, a tetrahedral mesh phantom, by converting a polygonal surface phantom to a tetrahedral mesh geometry. The constructed phantom was implemented in the Geant4 Monte Carlo code to calculate organ doses as well as to measure computation speed, the values were then compared with those for the original polygonal surface phantom. It was found that using the tetrahedral mesh phantom significantly improved the computation speed by factors of between 150 and 832 considering all of the particles and simulated energies other than the low-energy neutrons (0.01 and 1 MeV), for which the improvement was less significant (17.2 and 8.8 times, respectively). | - |
| dc.format.extent | 13 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Institute of Physics Publishing | - |
| dc.title | Tetrahedral-mesh-based computational human phantom for fast Monte Carlo dose calculations | - |
| dc.type | Article | - |
| dc.publisher.location | 영국 | - |
| dc.identifier.doi | 10.1088/0031-9155/59/12/3173 | - |
| dc.identifier.scopusid | 2-s2.0-84902437131 | - |
| dc.identifier.wosid | 000337176600017 | - |
| dc.identifier.bibliographicCitation | Physics in Medicine and Biology, v.59, no.12, pp 3173 - 3185 | - |
| dc.citation.title | Physics in Medicine and Biology | - |
| dc.citation.volume | 59 | - |
| dc.citation.number | 12 | - |
| dc.citation.startPage | 3173 | - |
| dc.citation.endPage | 3185 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Biomedical | - |
| dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
| dc.subject.keywordPlus | ADULT HUMAN PHANTOMS | - |
| dc.subject.keywordPlus | FEMALE | - |
| dc.subject.keywordPlus | DOSIMETRY | - |
| dc.subject.keywordPlus | SIZE | - |
| dc.subject.keywordPlus | GEANT4 | - |
| dc.subject.keywordPlus | POPULATIONS | - |
| dc.subject.keywordPlus | SIMULATION | - |
| dc.subject.keywordPlus | PATIENT | - |
| dc.subject.keywordAuthor | computational phantom | - |
| dc.subject.keywordAuthor | tetrahedron | - |
| dc.subject.keywordAuthor | Monte Carlo simulation | - |
| dc.subject.keywordAuthor | computation speed | - |
| dc.identifier.url | https://iopscience.iop.org/article/10.1088/0031-9155/59/12/3173 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
