Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Differential effect of 3-dimensional color Doppler echocardiography for the quantification of mitral regurgitation according to the severity and characteristics.

Authors
Choi, JaehukHeo, RanHong, Geu-RuChang, Hyuk-JaeSung, Ji MinShin, Sang HoonCho, In JeongShim, Chi-YoungChung, Namsik
Issue Date
May-2014
Publisher
LIPPINCOTT WILLIAMS & WILKINS
Keywords
echocardiography; mitral valve insufficiency
Citation
CIRCULATION-CARDIOVASCULAR IMAGING, v.7, no.3, pp.535 - 544
Indexed
SCIE
SCOPUS
Journal Title
CIRCULATION-CARDIOVASCULAR IMAGING
Volume
7
Number
3
Start Page
535
End Page
544
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/159962
DOI
10.1161/CIRCIMAGING.113.001457
ISSN
1941-9651
Abstract
Background-The aim of this study is to explore the differential effect of 3-dimensional color Doppler echocardiography for the quantification of mitral regurgitation (MR). Two-dimensional color Doppler echocardiography-based MR quantification has well-documented limitations. Methods and Results-We consecutively enrolled 221 patients with MR. Adequate image quality was obtained by 2D- and 3D-color Doppler echocardiography in 211 (95.5%) patients. The quantitative differences between the MR volumes obtained by 2D- and 3D-proximal isovelocity surface area (PISA) were analyzed in various MR subgroups. In the validation cohort (n=52), MR volume obtained by 3D-PISA showed a better agreement with phase-contrast cardiac MRI than 2D-PISA (r=0.97 versus 0.84). In all 211 patients, 2D-PISA underestimated the MR volume when compared with 3D-PISA (52.4 +/- 19.6 versus 59.5 +/- 25.6 mL; P=0.005). A total of 33.3% with severe MR based on 3D-PISA were incorrectly assessed by 2D-PISA as having nonsevere MR. In the subgroup analysis, the MR severity (odds ratio, 6.96; 95% confidence interval, 3.04-15.94; P<0.001) and having an asymmetrical orifice (odds ratio, 11.48; 95% confidence interval, 3.72-35.4; P<0.001), and an eccentric jet (odds ratio, 3.82; 95% confidence interval, 1.27-11.48; P=0.017) were predictors of significant difference in MR volume (>15 mL) between 2D- and 3D-PISA methods. Conclusions-Quantification of MR by 3D-PISA method is clinically feasible and more accurate than the current 2D-PISA method. MR quantification by 2D-PISA significantly underestimated MR volume with severe, eccentric MR with an asymmetrical orifice. This article demonstrates that 3D-color Doppler echocardiography could be used as a valuable tool to confirm treatment strategy in patients with significant MR.
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 내과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Heo, Ran photo

Heo, Ran
COLLEGE OF MEDICINE (DEPARTMENT OF INTERNAL MEDICINE)
Read more

Altmetrics

Total Views & Downloads

BROWSE