Multi-functional ceramic hybrid coatings on biodegradable AZ31 Mg implants: electrochemical, tribological and quantum chemical aspects for orthopaedic applications

Authors
Madhankumar, A.Thangavel, ElangovanRamakrishna, SureshObot, I. B.Jung, Hwa ChulShin, Kwang SeonGasem, Zuhair M.Kim, HyongbumKim, Dae-Eun
Issue Date
May-2014
Publisher
ROYAL SOC CHEMISTRY
Citation
RSC ADVANCES, v.4, no.46, pp.24272 - 24285
Indexed
SCIE
SCOPUS
Journal Title
RSC ADVANCES
Volume
4
Number
46
Start Page
24272
End Page
24285
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/160009
DOI
10.1039/c4ra02363c
ISSN
2046-2069
Abstract
Application of biodegradable implants has received increasing attention for the treatment of bone damage due to their low adverse effects. To achieve better biocompatibility and enhanced corrosion resistance of biodegradable implants with improved wear resistance, multifunctional coatings need to be developed. Herein, a ceramic hybrid coating has been fabricated by a plasma electrolytic oxidation (PEO) technique using Ta2O5 nanoparticle inclusion on AZ31 Mg alloy in order to attain superior corrosion, wear behavior, and surface porosity that enable improved bioactivity. X-ray diffraction analysis of PEO coatings showed that the surface coating is mainly composed of Mg-3(PO4)(2), MgO and Ta2O5 in different quantities based on PEO processing. Furthermore, scanning electron microscopy (SEM) analysis was employed to observe the surface of the resultant PEO hybrid coatings after and before wear tests. With Ta2O5 nanoparticles, PEO coatings showed excellent wear compared with pure PEO coatings. The efficiency of the hybrid coatings in corrosion protection was verified by the Tafel plot and electrochemical impedance spectroscopy measurements in simulated body fluid. Furthermore, in vitro cell culture studies were performed on MG-63 human cells to evaluate the biocompatibility of PEO coatings. A quantum chemical approach and force-field molecular dynamics simulation were employed to evaluate the interaction between the AZ31 Mg surface and PEO hybrid coatings. All of the observations evidently showed that the ceramic hybrid PEO coating provides improved wear and corrosion protection performance with superior biocompatibility with Ta2O5 nanoparticles, when compared to pure PEO coatings, due to its synergistic beneficial effect.
Files in This Item
Go to Link
Appears in
Collections
서울 의생명공학전문대학원 > 서울 의생명과학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Ramakrishna, Suresh photo

Ramakrishna, Suresh
GRADUATE SCHOOL OF BIOMEDICAL SCIENCE AND ENGINEERING (DEPARTMENT OF BIOMEDICAL SCIENCE)
Read more

Altmetrics

Total Views & Downloads

BROWSE