Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparison Between an Automated Device and a Manual Mercury Sphygmomanometer in an Epidemiological Survey of Hypertension Prevalence

Full metadata record
DC Field Value Language
dc.contributor.authorLim, Young-Hyo-
dc.contributor.authorChoi, Sung Yong-
dc.contributor.authorOh, Kyung Won-
dc.contributor.authorKim, Yuna-
dc.contributor.authorCho, Eun Sil-
dc.contributor.authorChoi, Bo Youl-
dc.contributor.authorKim, Yu-Mi-
dc.contributor.authorShin, Jinho-
dc.date.accessioned2022-07-16T05:23:15Z-
dc.date.available2022-07-16T05:23:15Z-
dc.date.created2021-05-12-
dc.date.issued2014-04-
dc.identifier.issn0895-7061-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/160287-
dc.description.abstractBACKGROUND Automated devices (AD) for measuring blood pressure (BP) are gradually replacing mercury sphygmomanometers (MM) in clinical settings. However, the use of ADs in epidemiological surveys has not been established. We investigated the factors associated with measurement differences when using an MM and an AD. METHODS Two trained observers took three BP measurements in 454 subjects as part of an epidemiological survey, alternately using an MM and an AD. BP measurement difference was defined as BPMM - BPAD. Alarm reactions (ARs) were calculated by subtracting the third systolic BP (SBP) measurement from the first SBP. RESULTS The mean age of subjects was 50.7 +/- 15.4 years (n = 454). The mean BPs using the MM and the AD were 119.8 +/- 13.9 vs. 119.5 +/- 13.6 mm Hg in males and 115.0 +/- 16.8 vs. 111.6 +/- 15.7 mm Hg in females for SBP and 77.7 +/- 10.4 vs. 74.7 +/- 10.4 mm Hg in males and 73.2 +/- 9.3 vs. 69.9 +/- 10.3 mm Hg in females for diastolic BP (DBP). Age, gender, arm circumference, and AR were the factors related to the difference. The concordance correlation coefficients for SBP and DBP were 0.8914 (95% confidence interval [CI], 0.8727-0.9102) and 0.8207 (95% CI, 0.7920-0.8494). The kappa values for the diagnosis of hypertension and Joint National Committee 7 BP classification were 0.6538 (0.5436-0.7641) and 0.5703 (0.5055-0.6351), respectively. The diagnostic sensitivity for hypertension was 59.0%. CONCLUSIONS Age, gender, arm circumference, and AR were the factors related to the differences. Despite small differences in the mean values, the agreement and reliability were not good enough to recommend the A&D UA-767PC for adoption in epidemiological surveys of hypertension prevalence.-
dc.language영어-
dc.language.isoen-
dc.publisherOXFORD UNIV PRESS-
dc.titleComparison Between an Automated Device and a Manual Mercury Sphygmomanometer in an Epidemiological Survey of Hypertension Prevalence-
dc.typeArticle-
dc.contributor.affiliatedAuthorLim, Young-Hyo-
dc.contributor.affiliatedAuthorChoi, Bo Youl-
dc.contributor.affiliatedAuthorShin, Jinho-
dc.identifier.doi10.1093/ajh/hpt100-
dc.identifier.scopusid2-s2.0-84897899729-
dc.identifier.wosid000333246600006-
dc.identifier.bibliographicCitationAMERICAN JOURNAL OF HYPERTENSION, v.27, no.4, pp.537 - 545-
dc.relation.isPartOfAMERICAN JOURNAL OF HYPERTENSION-
dc.citation.titleAMERICAN JOURNAL OF HYPERTENSION-
dc.citation.volume27-
dc.citation.number4-
dc.citation.startPage537-
dc.citation.endPage545-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaCardiovascular System & Cardiology-
dc.relation.journalWebOfScienceCategoryPeripheral Vascular Disease-
dc.subject.keywordPlusBLOOD-PRESSURE-MEASUREMENT-
dc.subject.keywordPlusPULSE PRESSURE-
dc.subject.keywordPlusPOPULATION-
dc.subject.keywordPlusGENDER-
dc.subject.keywordAuthorblood pressure-
dc.subject.keywordAuthordiagnostic errors-
dc.subject.keywordAuthorepidemiological factors-
dc.subject.keywordAuthorhypertension-
dc.subject.keywordAuthoroscillometry-
dc.identifier.urlhttps://academic.oup.com/ajh/article/27/4/537/2743162-
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 예방의학교실 > 1. Journal Articles
서울 의과대학 > 서울 내과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lim, Young-Hyo photo

Lim, Young-Hyo
COLLEGE OF MEDICINE (DEPARTMENT OF INTERNAL MEDICINE)
Read more

Altmetrics

Total Views & Downloads

BROWSE