접합부 회전성능에 따른 중간 철골 모멘트 골조의 내진성능 평가 - Ⅰ 성능평가
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 문기훈 | - |
| dc.contributor.author | 한상환 | - |
| dc.contributor.author | 하성진 | - |
| dc.date.accessioned | 2022-07-16T05:35:42Z | - |
| dc.date.available | 2022-07-16T05:35:42Z | - |
| dc.date.issued | 2014-03 | - |
| dc.identifier.issn | 1226-525X | - |
| dc.identifier.issn | 2234-1099 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/160427 | - |
| dc.description.abstract | The current AISC341-10 standard specifiesa value of 0.02 radian for the minimum rotation capacity of connections for the intermediatesteel moment frame system. However, despite of the advances realized in the domains of performance evaluation method and analysismethod, research onthe minimum rotation capacity of the intermediate steel moment frame systemsatisfying the seismic performance hasnot been conducted in detail. In this study, the intermediate moment frame systemisdesigned with respect to current standards and theseismic performance in accordance with the rotational capacity of connections is evaluated using the seismic performance evaluationmethod presented in FEMA-P695. The minimum rotation capacity of intermediate steel moment frames required to satisfy seismicperformance as well as the major design values affecting the seismic performance of moment frame areestimated. To that goal, the designparameters are selected and various target frames are designed. The analysis models of the main nonlinear elements are also developedfor evaluating seismic performance. The resultsshow that the 20-story structure doesnot meet the seismic performance even if it satisfiesthe rotation capacity of 0.02 radian. | - |
| dc.format.extent | 9 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국지진공학회 | - |
| dc.title | 접합부 회전성능에 따른 중간 철골 모멘트 골조의 내진성능 평가 - Ⅰ 성능평가 | - |
| dc.title.alternative | Seismic Performance Evaluation According to Rotation Capacity of Connections for Intermediate Steel Moment Frames - I. Performance Evaluation | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.5000/EESK.2014.18.2.95 | - |
| dc.identifier.bibliographicCitation | 한국지진공학회논문집, v.18, no.2, pp 95 - 103 | - |
| dc.citation.title | 한국지진공학회논문집 | - |
| dc.citation.volume | 18 | - |
| dc.citation.number | 2 | - |
| dc.citation.startPage | 95 | - |
| dc.citation.endPage | 103 | - |
| dc.identifier.kciid | ART001853432 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Intermediate moment frame | - |
| dc.subject.keywordAuthor | Rotation capacity | - |
| dc.subject.keywordAuthor | Seismic performance | - |
| dc.subject.keywordAuthor | FEMA 695 | - |
| dc.subject.keywordAuthor | Seismic design parameters | - |
| dc.identifier.url | http://koreascience.or.kr/article/JAKO201409150679791.page | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.