Cited 0 time in
중전압 계통 연계를 위한 멀티 센트럴 대용량 태양광 발전 시스템의 공통 모드 전압 억제
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 배영상 | - |
| dc.contributor.author | 김래영 | - |
| dc.date.accessioned | 2022-07-16T06:03:45Z | - |
| dc.date.available | 2022-07-16T06:03:45Z | - |
| dc.date.created | 2021-05-13 | - |
| dc.date.issued | 2014-02 | - |
| dc.identifier.issn | 1229-2214 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/160648 | - |
| dc.description.abstract | This paper describes an optimal configuration for multi-central inverters in a medium-voltage (MV) grid, which is suitable for large-scale photovoltaic (PV) power plants. We theoretically analyze a proposed common-mode equivalent model for problems associated with multi-central transformerless-type three-phase full bridge(3-FB) PV inverters employing two-winding MV transformers. We propose a synchronized PWM control strategy to effectively reduce the common-mode voltages that may simultaneously occur. In addition, we propose that the existing 3-FB topology may also have the configuration of a multi-central inverter with a two-winding MV transformer by making a simple circuit modification. Simulation and experimental results of three 350kW PV inverters in a multi-central configuration verify the effectiveness of the proposed synchronization control strategy. The modified transformerless-type 3-FB topology for a multi-central PV inverter configuration is verified using an experimental prototype of a 100kW PV inverter. | - |
| dc.language | 한국어 | - |
| dc.language.iso | ko | - |
| dc.publisher | 전력전자학회 | - |
| dc.title | 중전압 계통 연계를 위한 멀티 센트럴 대용량 태양광 발전 시스템의 공통 모드 전압 억제 | - |
| dc.title.alternative | Suppression of Common-Mode Voltage in a Multi-Central Large-Scale PV Generation Systems for Medium-Voltage Grid Connection | - |
| dc.type | Article | - |
| dc.contributor.affiliatedAuthor | 김래영 | - |
| dc.identifier.doi | 10.6113/TKPE.2014.19.1.31 | - |
| dc.identifier.bibliographicCitation | 전력전자학회 논문지, v.19, no.1, pp.31 - 40 | - |
| dc.relation.isPartOf | 전력전자학회 논문지 | - |
| dc.citation.title | 전력전자학회 논문지 | - |
| dc.citation.volume | 19 | - |
| dc.citation.number | 1 | - |
| dc.citation.startPage | 31 | - |
| dc.citation.endPage | 40 | - |
| dc.type.rims | ART | - |
| dc.identifier.kciid | ART001849290 | - |
| dc.description.journalClass | 2 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | central inverter | - |
| dc.subject.keywordAuthor | medium voltage | - |
| dc.subject.keywordAuthor | common mode | - |
| dc.subject.keywordAuthor | leakage current | - |
| dc.identifier.url | http://koreascience.or.kr/article/JAKO201408439035963.page | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.