Validation of RCS depressurization strategy and core coolability map for independent scenarios of SBLOCA, SBO, and TLOFW
- Authors
- Lee, Seongnyeon; Ha, Kwang Soon; Kim, Hwan-Yeol; Kim, Sung Joong
- Issue Date
- Feb-2014
- Publisher
- TAYLOR & FRANCIS LTD
- Keywords
- accident management; severe accident; in-vessel retention; LOCA; LWR-type reactor; PWR-type reactor
- Citation
- JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, v.51, no.2, pp.181 - 195
- Indexed
- SCIE
SCOPUS
- Journal Title
- JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY
- Volume
- 51
- Number
- 2
- Start Page
- 181
- End Page
- 195
- URI
- https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/160710
- DOI
- 10.1080/00223131.2014.854713
- ISSN
- 0022-3131
- Abstract
- Severe accident analysis for Small Break (SB), Middle Break (MB), and Large Break (LB) Loss-Of-Coolant Accident (LOCA), Station Black Out (SBO), Total Loss-Of-Feed-Water (TLOFW) was performed and effectiveness of Reactor Coolant System (RCS) depressurization strategies of OPR1000 was analyzed using MELCOR 1.8.6 code. Required injection flow rate has been derived using Core Exit Temperature (CET) information obtained from MELCOR calculation and a simple model and corresponding coolability map have been suggested to assist effective operator action. The depressurization strategies using secondary Atmospheric Dump Valve (ADV) for SBLOCA, pressurizer Safety Depressurization System (SDS) for SBO and TLOFW were introduced in 5min since the initiation of Severe Accident Management Guidance (SAMG). Respective mitigation strategy employed leads to significant delay of the reactor pressure vessel failure and RCS pressure at Reactor Pressure Vessel (RPV) failure was lower than the SAMG target pressure of 2.86 MPa. Thus, possibility of High Pressure Melt Ejection (HPME) and impair of containment building is expected to avoid effectively. Using CET information obtained from MELCOR calculation, a simple model and a coolability map for the required injection flow rate were developed for recovery of core coolability. It is suggested that the coolability map based on MELCOR calculation results may provide decisive and intuitive information to operators for more effective safety management.
- Files in This Item
-
Go to Link
- Appears in
Collections - 서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.