Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparison of a gasless unilateral axillo-breast and axillary approach in robotic thyroidectomy

Authors
Song, Chang MyeonCho, Yong HeeJi, Yong BaeJeong, Jin HyeokKim, Dong SunTae, Kyung
Issue Date
Oct-2013
Publisher
SPRINGER
Keywords
Robotic thyroidectomy; da Vinci Surgical System; Gasless unilateral axillo-breast approach; Gasless unilateral axillary approach; Endoscopic thyroidectomy; Cosmesis
Citation
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, v.27, no.10, pp.3769 - 3775
Indexed
SCIE
SCOPUS
Journal Title
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES
Volume
27
Number
10
Start Page
3769
End Page
3775
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/161880
DOI
10.1007/s00464-013-2964-x
ISSN
0930-2794
Abstract
Background: New approaches to robotic thyroidectomy help to prevent neck scarring and improve surgical ergonomics. The purpose of this study was to compare the efficacy and advantages of a gasless unilateral axillary (GUA) approach and an axillo-breast (GUAB) approach in robotic thyroidectomy. Methods: We retrospectively reviewed the data of 131 patients who underwent robotic thyroidectomy with or without central neck dissection using a GUAB (90 cases) or GUA (41 cases) approach between September 2009 and December 2011. We excluded patients who underwent simultaneous lateral neck dissection and cases within the learning curve. We compared patient and tumor characteristics, surgical outcomes, perioperative complications, and cosmetic satisfaction between the two approaches. Results: Robotic thyroidectomy was successful in all patients. There were no differences in terms of patient and tumor characteristics, extent of thyroidectomy and central neck dissection, operative time, and postoperative complications between the two approaches. Cosmetic satisfaction was excellent in both groups. There was no difference in satisfaction with the cosmetic result in the neck area, but the GUA patients expressed higher satisfaction with the appearance of the breast. Conclusions: The surgical outcomes of GUA and GUAB approaches are similar in robotic thyroidectomy. Both are safe, effective, and yield cosmetically excellent results when performed by an experienced robotic thyroid surgeon. However, a GUA approach is associated with superior cosmetic satisfaction with the appearance of the breast.
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 내과학교실 > 1. Journal Articles
서울 의과대학 > 서울 이비인후과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Ji, Yong Bae photo

Ji, Yong Bae
COLLEGE OF MEDICINE (DEPARTMENT OF OTOLARYNGOLOGY)
Read more

Altmetrics

Total Views & Downloads

BROWSE