Validation of intra- and interobserver reproducibility of shearwave elastography: Phantom study
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Mun, Han Song | - |
| dc.contributor.author | Choi, Seon Hyeong | - |
| dc.contributor.author | Kook, Shin Ho | - |
| dc.contributor.author | Choi, Yoonjung | - |
| dc.contributor.author | Jeong, Woo Kyoung | - |
| dc.contributor.author | Kim, Yongsoo | - |
| dc.date.accessioned | 2022-07-16T09:24:11Z | - |
| dc.date.available | 2022-07-16T09:24:11Z | - |
| dc.date.issued | 2013-07 | - |
| dc.identifier.issn | 0041-624X | - |
| dc.identifier.issn | 1874-9968 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/162450 | - |
| dc.description.abstract | Purpose: To assess intra- and interobserver reproducibility of quantitative ultrasound (US) elastography for breast masses using shearwave elastography (SWE). Materials and methods: The US elastography phantom was used. This training phantom contained 12 masses with dimensions from 6 to 11 mm and varying B-mode (hypo- iso- and hyperechoic) characteristics and viscoelastic properties varying from about 50 to 250 kPa. Four attending radiologists participated as operators and used Supersonic Imaging 15-4 MHz array to acquire images. In each session, B-mode US features were assessed once and US elastography values were assessed twice in a consecutive and distinct manner. A total of three identical sessions of data acquisition were performed at 2-week intervals. For categorical variables such as BI-RADS features of mass on B-mode image and qualitative SWE features, kappa (k) values were calculated by the generalized linear mixed model. For continuous variables, kPa, and ratio, intraclass correlation coefficients (ICCs) were calculated. Results: Interobserver agreement for SWE image similarity was moderate (k = 0.57). With respect to quantitative SWE values, intraobserver ICCs were 0.65, 0.77, 0.92, and 0.91 for maximum elasticity; 0.70, 0.83, 0.94, and 0.94 for mean elasticity; and 0.67, 0.83, 0.92, and 0.92 for elasticity ratio for operators 1, 2, 3, and 4, respectively. Interobserver reproducibility showed good agreement with ICC values of 0.77 for maximum elasticity, 0.82 for mean elasticity, and 0.79 for elasticity ratio. Conclusion: Quantitative US elastography for breast masses was highly reproducible with good agreement across operators. With respect to intraobserver reproducibility, ICC values varied but three out of four operators showed good agreement. (C) 2013 Elsevier B. V. All rights reserved. | - |
| dc.format.extent | 5 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Elsevier BV | - |
| dc.title | Validation of intra- and interobserver reproducibility of shearwave elastography: Phantom study | - |
| dc.type | Article | - |
| dc.publisher.location | 네델란드 | - |
| dc.identifier.doi | 10.1016/j.ultras.2013.01.013 | - |
| dc.identifier.scopusid | 2-s2.0-84876052288 | - |
| dc.identifier.wosid | 000317184400015 | - |
| dc.identifier.bibliographicCitation | Ultrasonics, v.53, no.5, pp 1039 - 1043 | - |
| dc.citation.title | Ultrasonics | - |
| dc.citation.volume | 53 | - |
| dc.citation.number | 5 | - |
| dc.citation.startPage | 1039 | - |
| dc.citation.endPage | 1043 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Acoustics | - |
| dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
| dc.relation.journalWebOfScienceCategory | Acoustics | - |
| dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
| dc.subject.keywordPlus | BREAST-LESIONS | - |
| dc.subject.keywordPlus | MASSES | - |
| dc.subject.keywordAuthor | Ultrasound | - |
| dc.subject.keywordAuthor | Elastography | - |
| dc.subject.keywordAuthor | Shearwave elastography | - |
| dc.subject.keywordAuthor | Reproducibility | - |
| dc.subject.keywordAuthor | Phantom | - |
| dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S0041624X13000310?via%3Dihub | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.