Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Effective Preprocessing Procedures Virtually Eliminate Distance-Dependent Motion Artifacts in Resting State FMRI

Full metadata record
DC Field Value Language
dc.contributor.authorJo, Hang Joon-
dc.contributor.authorGotts, Stephen J.-
dc.contributor.authorReynolds, Richar-
dc.contributor.authorBandettini, Pe-
dc.contributor.authorMartin, Alex-
dc.contributor.authorCox, Robert W.-
dc.contributor.authorSaad, Ziad S.-
dc.date.accessioned2022-07-16T09:30:34Z-
dc.date.available2022-07-16T09:30:34Z-
dc.date.created2021-05-13-
dc.date.issued2013-06-
dc.identifier.issn1110-757X-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/162531-
dc.description.abstractArtifactual sources of resting-state (RS) FMRI can originate from head motion, physiology, and hardware. Of these sources, motion has received considerable attention and was found to induce corrupting effects by differentially biasing correlations between regions depending on their distance. Numerous corrective approaches have relied on the identification and censoring of high-motion time points and the use of the brain-wide average time series as a nuisance regressor to which the data are orthogonalized (Global Signal Regression, GSReg). We replicate the previously reported head-motion bias on correlation coefficients and then show that while motion can be the source of artifact in correlations, the distance-dependent bias is exacerbated by GSReg. Put differently, correlation estimates obtained after GSReg are more susceptible to the presence of motion and by extension to the levels of censoring. More generally, the effect of motion on correlation estimates depends on the preprocessing steps leading to the correlation estimate, with certain approaches performing markedly worse than others. For this purpose, we consider various models for RS FMRI preprocessing and show that the local white matter regressor (WMeLOCAL), a subset of ANATICOR, results in minimal sensitivity to motion and reduces by extension the dependence of correlation results on censoring.-
dc.language영어-
dc.language.isoen-
dc.publisherHINDAWI PUBLISHING CORPORATION-
dc.titleEffective Preprocessing Procedures Virtually Eliminate Distance-Dependent Motion Artifacts in Resting State FMRI-
dc.typeArticle-
dc.contributor.affiliatedAuthorJo, Hang Joon-
dc.identifier.doi10.1155/2013/935154-
dc.identifier.scopusid2-s2.0-84880140628-
dc.identifier.wosid000320804400001-
dc.identifier.bibliographicCitationJOURNAL OF APPLIED MATHEMATICS, v.2013, pp.1 - 9-
dc.relation.isPartOfJOURNAL OF APPLIED MATHEMATICS-
dc.citation.titleJOURNAL OF APPLIED MATHEMATICS-
dc.citation.volume2013-
dc.citation.startPage1-
dc.citation.endPage9-
dc.type.rimsART-
dc.type.docType정기학술지(Article(Perspective Article포함))-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaMathematics-
dc.relation.journalWebOfScienceCategoryMathematics, Applied-
dc.relation.journalWebOfScienceCategoryMathematics, Interdisciplinary Applications-
dc.subject.keywordPlusFUNCTIONAL CONNECTIVITY-
dc.subject.keywordPlusMRI-
dc.subject.keywordPlusREGRESSION-
Files in This Item
There are no files associated with this item.
Appears in
Collections
서울 의과대학 > 서울 생리학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jo, Hang Joon photo

Jo, Hang Joon
COLLEGE OF MEDICINE (DEPARTMENT OF PHYSIOLOGY)
Read more

Altmetrics

Total Views & Downloads

BROWSE