Cited 0 time in
Stylet- or forceps-guided tube exchanger to facilitate GlideScope (R) intubation in simulated difficult intubations - a randomised controlled trial
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Jeon, W. J. | - |
| dc.contributor.author | Shim, J. H. | - |
| dc.contributor.author | Cho, S. Y. | - |
| dc.contributor.author | Baek, S. J. | - |
| dc.date.accessioned | 2022-07-16T09:44:50Z | - |
| dc.date.available | 2022-07-16T09:44:50Z | - |
| dc.date.issued | 2013-06 | - |
| dc.identifier.issn | 0003-2409 | - |
| dc.identifier.issn | 1365-2044 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/162699 | - |
| dc.description.abstract | The GlideScope (R) videolaryngoscope is widely used in the management of the difficult airway. However, passing the tracheal tube through the vocal cords can be awkward, and the use of a stylet to guide insertion is recommended. This randomised controlled trial evaluated a forceps-guided tube exchanger as an alternative to the stylet to aid intubation with the GlideScope in patients undergoing anaesthesia, with a simulated difficult airway created by the application of a semi-rigid cervical collar. Data were analysed from 178 patients randomly assigned to undergo intubation using either the stylet (n=88) or a forceps-guided tube exchanger (n=90). All intubations were completed successfully, with first attempt rates of 93.2% using the stylet and 94.4% using the exchanger (p=0.597). The mean (SD) intubation time was 67.8 (28.7) s in the stylet group and 66.1 (15.5) s in the forceps-guided tube exchanger group (p=0.11). The frequency of sore throat 1h after extubation was 34.1% in the stylet group and 2.2% in the tube exchanger group (p<0.001); 24h after extubation the corresponding figures were 40.0% and 11.1% (p<0.001). Using a forceps-guided tube exchanger may offer an advantage over a stylet in guiding tracheal intubation when the GlideScope is used. | - |
| dc.format.extent | 6 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Blackwell Publishing Inc. | - |
| dc.title | Stylet- or forceps-guided tube exchanger to facilitate GlideScope (R) intubation in simulated difficult intubations - a randomised controlled trial | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1111/anae.12219 | - |
| dc.identifier.scopusid | 2-s2.0-84877729648 | - |
| dc.identifier.wosid | 000318811500007 | - |
| dc.identifier.bibliographicCitation | Anaesthesia, v.68, no.6, pp 585 - 590 | - |
| dc.citation.title | Anaesthesia | - |
| dc.citation.volume | 68 | - |
| dc.citation.number | 6 | - |
| dc.citation.startPage | 585 | - |
| dc.citation.endPage | 590 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Anesthesiology | - |
| dc.relation.journalWebOfScienceCategory | Anesthesiology | - |
| dc.subject.keywordPlus | CERVICAL-SPINE IMMOBILIZATION | - |
| dc.subject.keywordPlus | VIDEO LARYNGOSCOPE | - |
| dc.subject.keywordPlus | OROTRACHEAL INTUBATION | - |
| dc.subject.keywordPlus | MACINTOSH LARYNGOSCOPE | - |
| dc.subject.keywordPlus | TRACHEAL INTUBATION | - |
| dc.subject.keywordPlus | VIDEOLARYNGOSCOPE | - |
| dc.subject.keywordPlus | COMPLICATIONS | - |
| dc.subject.keywordPlus | MANAGEMENT | - |
| dc.subject.keywordPlus | INTRODUCER | - |
| dc.subject.keywordPlus | SYSTEM | - |
| dc.identifier.url | https://associationofanaesthetists-publications.onlinelibrary.wiley.com/doi/10.1111/anae.12219 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
