공조기를 이용한 외피 기밀도 실측 및 분석
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 한슬기 | - |
dc.contributor.author | 김민휘 | - |
dc.contributor.author | 정재원 | - |
dc.date.accessioned | 2022-07-16T10:18:09Z | - |
dc.date.available | 2022-07-16T10:18:09Z | - |
dc.date.created | 2021-05-13 | - |
dc.date.issued | 2013-04 | - |
dc.identifier.issn | 2287-5786 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/162956 | - |
dc.description.abstract | This research is a case study performing the air-handler fan pressurization test in two office building.The test has beenfollowing the existing test standard(i.e.ASTM E779-10, CAN/CGSB-149.15-96 Standard).The test building is a 5-story officewith a square(32.4m x 32.4m) footprint built in 2001 at Daejeon.Another test building is a 12-story offce building with asquare(34.9m x 34.9m) at Seoul.Before the test, the standards about air leakage test is analyzed.Then, the pressure differencemeasurement is apply to ASTM standard.This paper provides some practical information acquired in the field measurement ofair tightness test using the established air-handler fan pressurization test method. | - |
dc.language | 한국어 | - |
dc.language.iso | ko | - |
dc.publisher | 대한건축학회 | - |
dc.title | 공조기를 이용한 외피 기밀도 실측 및 분석 | - |
dc.title.alternative | Estimation of air-handler fan pressurization test applicability based on the field measurement | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | 정재원 | - |
dc.identifier.bibliographicCitation | 대한건축학회 춘계학술발표대회논문집, v.33, no.1, pp.277 - 278 | - |
dc.relation.isPartOf | 대한건축학회 춘계학술발표대회논문집 | - |
dc.citation.title | 대한건축학회 춘계학술발표대회논문집 | - |
dc.citation.volume | 33 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 277 | - |
dc.citation.endPage | 278 | - |
dc.type.rims | ART | - |
dc.type.docType | Proceeding | - |
dc.description.journalClass | 2 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | other | - |
dc.subject.keywordAuthor | 팬 가압 테스트 | - |
dc.subject.keywordAuthor | 건물 기밀 성능 | - |
dc.subject.keywordAuthor | 기밀도 실측 | - |
dc.subject.keywordAuthor | Air-tightness Test | - |
dc.subject.keywordAuthor | Fan pressurization Test | - |
dc.subject.keywordAuthor | Air leakage | - |
dc.identifier.url | https://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE02216445 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1365
COPYRIGHT © 2021 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.