Cited 0 time in
Revision Total Knee Arthroplasty Using a Constrained Condylar Knee Prosthesis in Conjunction with A Posterior Stabilized Articular Polyethylene
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Lee, Jin Kyu | - |
| dc.contributor.author | Kim, Sung-Jae | - |
| dc.contributor.author | Choi, Choong H. | - |
| dc.contributor.author | Chung, Hyun-Kee | - |
| dc.date.accessioned | 2022-07-16T10:27:58Z | - |
| dc.date.available | 2022-07-16T10:27:58Z | - |
| dc.date.issued | 2013-04 | - |
| dc.identifier.issn | 0883-5403 | - |
| dc.identifier.issn | 1532-8406 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/163079 | - |
| dc.description.abstract | Legacy constrained condylar knee (LCCK) components are designed in the way that they can also be used in conjunction with a posterior-stabilized (PS) polyethylene insert, when adequate collateral stability is present. This study comprised 27 revision total knee arthroplasties (TKA) treated using an LCCK prosthesis and a PS polyethylene insert. Substantial range of motion and Knee Society score improvements were achieved in all subjects. Radiolucent lines between the block-cement were noted in 6 of 27 knees, but not significant. During TKA requiring the use of a femoral augment or stem extension, the design offering least constraint can be chosen, and an LCCK prosthesis with a PS polyethylene insert could be a satisfactory option. | - |
| dc.format.extent | 4 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Churchill Livingstone | - |
| dc.title | Revision Total Knee Arthroplasty Using a Constrained Condylar Knee Prosthesis in Conjunction with A Posterior Stabilized Articular Polyethylene | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1016/j.arth.2012.07.017 | - |
| dc.identifier.scopusid | 2-s2.0-84875098661 | - |
| dc.identifier.wosid | 000316922200006 | - |
| dc.identifier.bibliographicCitation | Journal of Arthroplasty, v.28, no.4, pp 566 - 569 | - |
| dc.citation.title | Journal of Arthroplasty | - |
| dc.citation.volume | 28 | - |
| dc.citation.number | 4 | - |
| dc.citation.startPage | 566 | - |
| dc.citation.endPage | 569 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Orthopedics | - |
| dc.relation.journalWebOfScienceCategory | Orthopedics | - |
| dc.subject.keywordPlus | ROTATING HINGE | - |
| dc.subject.keywordPlus | SYSTEM | - |
| dc.subject.keywordAuthor | knee | - |
| dc.subject.keywordAuthor | revision total knee arthroplasty | - |
| dc.subject.keywordAuthor | constrained condylar knee | - |
| dc.subject.keywordAuthor | posterior stabilized polyethylene | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
