Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Videographic Analysis of Glottic View With Increasing Cricoid Pressure Force

Authors
Oh, JaehoonLim, TaehoChee, YoungjoonKang, HyunggooCho, YoungsukLee, JongshillKim, DongwonJeong, Miae
Issue Date
Apr-2013
Publisher
MOSBY-ELSEVIER
Citation
ANNALS OF EMERGENCY MEDICINE, v.61, no.4, pp.407 - 413
Indexed
SCIE
SCOPUS
Journal Title
ANNALS OF EMERGENCY MEDICINE
Volume
61
Number
4
Start Page
407
End Page
413
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/163088
DOI
10.1016/j.annemergmed.2012.10.038
ISSN
0196-0644
Abstract
Study objective: Cricoid pressure may negatively affect laryngeal view and compromise airway patency, according to previous studies of direct laryngoscopy, endoscopy, and radiologic imaging. In this study, we assess the effect of cricoid pressure on laryngeal view with a video laryngoscope, the Pentax-AWS. Methods: This cross-sectional survey involved 50 American Society of Anesthesiologists status I and II patients who were scheduled to undergo elective surgery. The force measurement sensor for cricoid pressure and the video recording system using a Pentax-AWS video laryngoscope were newly developed by the authors. After force and video were recorded simultaneously, 11 still images were selected per 5-N (Newton; 1 N = 1 kg.m.s(-2)) increments, from 0 N to 50 N for each patient. The effect of cricoid pressure was assessed by relative percentage compared with the number of pixels on an image at 0 N. Results: Compared with zero cricoid pressure, the median percentage of glottic view visible was 89.5% (interquartile range [IQR] 64.2% to 117.1%) at 10 N, 83.2% (IQR 44.2% to 113.7%) at 20 N, 76.4% (IQR 34.1% to 109.1%) at 30 N, 51.0% (IQR 21.8% to 104.2%) at 40 N, and 47.6% (IQR 15.2% to 107.4%) at 50 N. The number of subjects who showed unworsened views was 20 (40%) at 10 N, 17 (34%) at 20 and 30 N, and 13 (26%) at 40 and 50 N. Conclusion: Cricoid pressure application with increasing force resulted in a worse glottic view, as examined with the Pentax-AWS Video laryngoscope. There is much individual difference in the degree of change, even with the same force. Clinicians should be aware that cricoid pressure affects laryngeal view with the Pentax-AWS and likely other video laryngoscopes. [Ann Emerg Med. 2013;61:407-413.]
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 마취통증의학교실 > 1. Journal Articles
서울 의과대학 > 서울 응급의학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Oh, Jae hoon photo

Oh, Jae hoon
COLLEGE OF MEDICINE (DEPARTMENT OF EMERGENCY MEDICINE)
Read more

Altmetrics

Total Views & Downloads

BROWSE