| dc.description.abstract | The aim of this study was to develop a new method to operate an interior permanent magnet synchronous machine (IPMSM) on the maximum torque per ampere (MTPA) condition. The characteristics of the MTPA condition were analyzed and the MTPA condition was derived based on the input electric power. The proposed method injects a small current signal used for tracking the MTPA operating point along with the fundamental current for torque generation. This method does not require any machine parameters or premade lookup table. The frequency of the injected signal is several hundred hertz, and the performance of the MTPA tracking is almost free from load torque disturbance. The feasibility of the proposed method was verified under various operating conditions with computer simulation and testing with an 11 kW IPMSM drive system. | - |
| dc.format.extent | 10 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Institute of Electrical and Electronics Engineers | - |
| dc.title | Maximum torque per ampere (MTPA) control of IPM machine based on signal injection considering inductance saturation | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1109/TPEL.2012.2195203 | - |
| dc.identifier.scopusid | 2-s2.0-84866507677 | - |
| dc.identifier.wosid | 000314694500048 | - |
| dc.identifier.bibliographicCitation | IEEE Transactions on Power Electronics, v.28, no.1, pp 488 - 497 | - |
| dc.citation.title | IEEE Transactions on Power Electronics | - |
| dc.citation.volume | 28 | - |
| dc.citation.number | 1 | - |
| dc.citation.startPage | 488 | - |
| dc.citation.endPage | 497 | - |
| dc.type.docType | 정기학술지(Article(Perspective Article포함)) | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.subject.keywordAuthor | Efficiency operation | - |
| dc.subject.keywordAuthor | interior permanent magnet synchronous machine (IPMSM) | - |
| dc.subject.keywordAuthor | maximum torque per ampere (MTPA) | - |
| dc.subject.keywordAuthor | signal injection | - |
| dc.identifier.url | https://ieeexplore.ieee.org/document/6186830 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.