Determination of the beam quality correction factor for the microLion chamber in a clinical photon beam

Full metadata record
DC Field Value Language
dc.contributor.authorChoi, Sang Hyoun-
dc.contributor.authorKim, Chan Hyeong-
dc.contributor.authorDo Huh, Hyun-
dc.contributor.authorKim, Kum-Bae-
dc.contributor.authorKim, SeongHoon-
dc.date.accessioned2022-07-16T11:45:56Z-
dc.date.available2022-07-16T11:45:56Z-
dc.date.created2021-05-12-
dc.date.issued2013-01-
dc.identifier.issn0374-4884-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/163678-
dc.description.abstractThe mcroLion chamber, which has a small volume (0.0017cc) and a high sensitivity suitable for small field dosimetry, is an ionization chamber with liquid (isooctane) filling the cavity volume. In the present work, we used two alternative ways to estimate the beam quality correction factor of the microLion chamber in the 6 MV photon beam from a Clinac iX accelerator (Varian, USA); Monte Carlo simulations and experimental methods. The Monte Carlo calculation (1.0183 +/- 0.58%) agreed to within 0.56% with the experimental determination (1.024 +/- 0.58%). The results from the two methods were in good agreement within acceptable uncertainties. We think that the averaged factor, 1.0212, could be used for the microLion chamber in reference dosimetry.-
dc.language영어-
dc.language.isoen-
dc.publisherKOREAN PHYSICAL SOC-
dc.titleDetermination of the beam quality correction factor for the microLion chamber in a clinical photon beam-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Chan Hyeong-
dc.identifier.doi10.3938/jkps.62.152-
dc.identifier.scopusid2-s2.0-84872813469-
dc.identifier.wosid000313957100027-
dc.identifier.bibliographicCitationJOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.62, no.1, pp.152 - 158-
dc.relation.isPartOfJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.citation.titleJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.citation.volume62-
dc.citation.number1-
dc.citation.startPage152-
dc.citation.endPage158-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.identifier.kciidART001736891-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryPhysics, Multidisciplinary-
dc.subject.keywordPlusLIQUID IONIZATION CHAMBERS-
dc.subject.keywordPlusMONTE-CARLO SIMULATIONS-
dc.subject.keywordPlusHIGH-ENERGY PHOTON-
dc.subject.keywordPlusREFERENCE DOSIMETRY-
dc.subject.keywordPlusSMALL FIELDS-
dc.subject.keywordPlusDETECTORS-
dc.subject.keywordAuthorBeam quality correction factor-
dc.subject.keywordAuthorMicroLion chamber-
dc.subject.keywordAuthorMonte Carlo simulation-
dc.identifier.urlhttps://link.springer.com/article/10.3938%2Fjkps.62.152-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE