Cited 0 time in
Management of Tibial Bony Defect with Metal Block in Primary Total Knee Replacement Arthroplasty
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Baek, Seung-Wook | - |
| dc.contributor.author | Kim, Chul-Woong | - |
| dc.contributor.author | Choi, Choong Hyeok | - |
| dc.date.accessioned | 2022-07-16T12:02:00Z | - |
| dc.date.available | 2022-07-16T12:02:00Z | - |
| dc.date.issued | 2013-00 | - |
| dc.identifier.issn | 2234-0726 | - |
| dc.identifier.issn | 2234-2451 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/163800 | - |
| dc.description.abstract | Purpose To analyze minimum 2-year clinical and radiological follow-up results of primary total knee replacement arthroplasty (TKRA) with metal block augmentation for tibial bony defect. Materials and Methods We analyzed 67 cases (52 patients) of primary TKRA with metal block augmentation for tibial bony defects from March 1999 and March 2008. Clinical results were evaluated using the Knee Society clinical rating system and the Western Ontario and McMaster University (WOMAC) score. Radiologic results were evaluated using the Knee Society roentgenographic evaluation system. Results The mean knee score and function score improved from 42.0 and 45.6 preoperatively to 94.5 and 85.4 postoperatively. At last follow-up, the mean WOMAC score was 16.8. The incidence of radiolucent lines was 10% (7 cases) during the follow-up period, but there was no case of progression. There were no statistically significant differences between the groups divided according to the block size (below 5 mm and over 8 mm) and between the stem and no-stem groups for all parameters. Conclusions Primary TKRA with a metal block produced satisfactory results for the minimum 2-year follow-up and can be considered as a simple and effective method for the treatment of tibial bony defect in primary TKRA. | - |
| dc.format.extent | 6 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | 대한슬관절학회 | - |
| dc.title | Management of Tibial Bony Defect with Metal Block in Primary Total Knee Replacement Arthroplasty | - |
| dc.type | Article | - |
| dc.identifier.doi | 10.5792/ksrr.2013.25.1.7 | - |
| dc.identifier.bibliographicCitation | Knee Surgery and Related Research, v.25, no.1, pp 7 - 12 | - |
| dc.citation.title | Knee Surgery and Related Research | - |
| dc.citation.volume | 25 | - |
| dc.citation.number | 1 | - |
| dc.citation.startPage | 7 | - |
| dc.citation.endPage | 12 | - |
| dc.identifier.kciid | ART001743281 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kciCandi | - |
| dc.subject.keywordAuthor | Total knee replacement arthroplasty | - |
| dc.subject.keywordAuthor | Bony defect | - |
| dc.subject.keywordAuthor | Metal block | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.