Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Electrical stimulation of the epiradicular space using a catheter with a removable stylet

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Dong Won-
dc.contributor.authorShim, Jae-Hang-
dc.contributor.authorJae, Hyun Cho-
dc.contributor.authorMin, Serk Kang-
dc.contributor.authorJEONG, JI SEON-
dc.contributor.authorShim, Jae Chol-
dc.date.accessioned2022-07-16T12:02:33Z-
dc.date.available2022-07-16T12:02:33Z-
dc.date.created2021-05-13-
dc.date.issued2013-
dc.identifier.issn1975-5171-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/163807-
dc.description.abstractBackground: Electrical stimulation can be used to verify the location of epidural catheters. Although epiradicular localization of a catheter is important for patients with radiating pain in the lower extremities due to spinal stenosis or disc herniation, no prospective study results pertaining to the stimulation threshold within the epiradicular space have been reported. Therefore, we set out to investigate the threshold current for motor response in the epiradicular space by the use of a catheter containing a removable stylet. In addition, this study examines the reliability of such epiradicular stimulation. Methods: In 105 patients undergoing a retrograde interlaminar ventral epidural injection, a lumbar epiradicular catheter was inserted. Loss of resistance was used to identify the epidural space. Afterward, the TheraCath was advanced into the epiradicular space and connected to a nerve stimulator. A nerve stimulator delivered progressively, increasing electrical current until an appropriate muscle contraction was observed. Contrast media was then injected and epiradicular dispersal was assessed. Results: Epiradicular stimulation yielded a mean threshold of 0.56± 0.50 mA (range: 0.06 to 2.84). When compared with epiradicular dispersal as a gold standard, the sensitivity, specificity, positive predictive value, and negative predictive value of epiradicular stimulation with the TheraCath were 90%, 56%, 96% and 33%,respectively. Conclusions: The threshold current of an insulated needle required to elicit a motor response in the epiradicular space was evaluated. We conclude that the epiradicular stimulation test is useful for confirming catheter placement. Nonetheless, further studies are required before implementing its routine use in clinical settings.-
dc.language영어-
dc.language.isoen-
dc.publisher대한마취통증의학회-
dc.titleElectrical stimulation of the epiradicular space using a catheter with a removable stylet-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Dong Won-
dc.contributor.affiliatedAuthorShim, Jae-Hang-
dc.identifier.bibliographicCitationAnesthesia and Pain Medicine, v.7, no.3, pp.221 - 225-
dc.relation.isPartOfAnesthesia and Pain Medicine-
dc.citation.titleAnesthesia and Pain Medicine-
dc.citation.volume7-
dc.citation.number3-
dc.citation.startPage221-
dc.citation.endPage225-
dc.type.rimsART-
dc.identifier.kciidART001682732-
dc.description.journalClass2-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasskci-
dc.description.journalRegisteredClassother-
dc.subject.keywordAuthorEpidural-
dc.subject.keywordAuthorEpiradicular-
dc.subject.keywordAuthorReliability-
dc.subject.keywordAuthorThreshold current-
Files in This Item
There are no files associated with this item.
Appears in
Collections
서울 의과대학 > 서울 마취통증의학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Dong Won photo

Kim, Dong Won
COLLEGE OF MEDICINE (DEPARTMENT OF ANESTHESIA AND MEDICINE)
Read more

Altmetrics

Total Views & Downloads

BROWSE