조적조 비내력벽을 가진 기존 학교 구조물의 내진 성능 평가
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 문기훈 | - |
dc.contributor.author | 전용률 | - |
dc.contributor.author | 이창석 | - |
dc.contributor.author | 한상환 | - |
dc.date.accessioned | 2022-07-16T12:10:45Z | - |
dc.date.available | 2022-07-16T12:10:45Z | - |
dc.date.created | 2021-05-13 | - |
dc.date.issued | 2012-12 | - |
dc.identifier.issn | 1226-525X | - |
dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/163909 | - |
dc.description.abstract | In Korea, most existing school buildings have been constructed with moment frames with un-reinforced infill walls designed only considering gravity loads. Thus, the buildings may not perform satisfactorily during earthquakes expected in Korea. In exterior frames of the building, un-reinforced masonry infill walls with window openings are commonly placed, which may alter the structural behavior of adjacent columns due to the interaction between the wall and column. The objective of this study is to evaluate the seismic performance of existing school buildings according to the procedure specified in ATC 63. Analytical models are proposed to simulate the structural behavior of columns, infill walls and their interaction. The accuracy of the proposed model is verified by comparing the analytical results with the experimental test results for one bay frames with and without infill walls with openings. For seismic performance evaluation, three story buildings are considered as model frames located at sites having different soil conditions (S_A, S_B, S_C, S_D, S_E) in Korea. It is observed that columns behaves as a short columns governed by shear due to infill masonry walls with openings. The collapse probabilities of the frames under maximum considered earthquake ranges from 62.9 to 99.5 %, which far exceed the allowable value specified in ATC 63. | - |
dc.language | 한국어 | - |
dc.language.iso | ko | - |
dc.publisher | 한국지진공학회 | - |
dc.title | 조적조 비내력벽을 가진 기존 학교 구조물의 내진 성능 평가 | - |
dc.title.alternative | Evaluation of Performance of Korean Existing School Buildings with Masonry Infilled Walls Against Earthquakes | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | 한상환 | - |
dc.identifier.doi | 10.5000/EESK.2012.16.6.037 | - |
dc.identifier.bibliographicCitation | 한국지진공학회논문집, v.16, no.6, pp.37 - 46 | - |
dc.relation.isPartOf | 한국지진공학회논문집 | - |
dc.citation.title | 한국지진공학회논문집 | - |
dc.citation.volume | 16 | - |
dc.citation.number | 6 | - |
dc.citation.startPage | 37 | - |
dc.citation.endPage | 46 | - |
dc.type.rims | ART | - |
dc.identifier.kciid | ART001723768 | - |
dc.description.journalClass | 2 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordAuthor | School structure | - |
dc.subject.keywordAuthor | Seismic performance evaluation | - |
dc.subject.keywordAuthor | Short column effect | - |
dc.subject.keywordAuthor | Masonry infill wall | - |
dc.subject.keywordAuthor | Shear failure | - |
dc.subject.keywordAuthor | ATC 63 | - |
dc.identifier.url | http://koreascience.or.kr/article/JAKO201205061577804.page | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1365
COPYRIGHT © 2021 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.