dc.description.abstract | This study was performed to optimize the basic platform of a lateral flow immunoassay. Improvement of the limit of detection (LOD) was evaluated according to the width of a nitrocellulose membrane with varying concentrations of analyte. The analyte, neutravidin was detected based on the avidin-biotin interaction. The antibody-Au nanoparticle conjugation was mostly stabled in a PBS buffer of pH 7.3. The optimal widths of a nitrocellulose membrane were 4and 6 mm considering the sample flow rate and signal strength of the test line on the membrane. The LOD of neutravidin was 0.001 mg/ml in the optimum conditions. | - |
dc.language | 한국어 | - |
dc.language.iso | ko | - |
dc.publisher | 충남대학교 농업과학연구소 | - |
dc.title | 뉴트라비딘 검출용 간이 진단키트의 성능향상을 위한 기본 플랫폼 선정 | - |
dc.title.alternative | The selection of basic platform for improving the sensitivity of neutravidin rapid detection kit | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | 엄애선 | - |
dc.identifier.doi | 10.7744/cnujas.2012.39.4.613 | - |
dc.identifier.bibliographicCitation | Korean Journal of Agricultural Science, v.39, no.4, pp.613 - 618 | - |
dc.relation.isPartOf | Korean Journal of Agricultural Science | - |
dc.citation.title | Korean Journal of Agricultural Science | - |
dc.citation.volume | 39 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 613 | - |
dc.citation.endPage | 618 | - |
dc.type.rims | ART | - |
dc.identifier.kciid | ART001734479 | - |
dc.description.journalClass | 2 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | kci | - |
dc.description.journalRegisteredClass | other | - |
dc.subject.keywordAuthor | Rapid detection kit | - |
dc.subject.keywordAuthor | Nitrocellulose membrane | - |
dc.subject.keywordAuthor | Avidin-biotin interaction | - |
dc.identifier.url | http://koreascience.or.kr/article/JAKO201213660552706.page | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1365
COPYRIGHT © 2021 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.