A sensorless control using Extended Kalman Filter for an IPM synchronous motor based on an extended rotor flux
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kim, Jae-Hoon | - |
| dc.contributor.author | Lee, Sang-soo | - |
| dc.contributor.author | Kim, Rae-Young | - |
| dc.contributor.author | Hyun, Dong-Seok | - |
| dc.date.accessioned | 2022-07-16T12:17:45Z | - |
| dc.date.available | 2022-07-16T12:17:45Z | - |
| dc.date.created | 2021-05-13 | - |
| dc.date.issued | 2012-12 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/164012 | - |
| dc.description.abstract | In this paper, a sensorless control of an interior permanent magnet synchronous motors (IPMSMs) is proposed using an Extended Kalman Filter (EKF) based on the extended rotor flux concept. Also, simple parameter estimation method is proposed to improve the performance of sensorless drive method. The IPMSM sensorless drive system has nonlinearity charac-teristics and parameters variation. To overcome two main drawbacks, the estimation of Extended rotor flux using the EKF is suitable for high performance because of its ability to perform state estimation for nonlinear systems that involve random noise environment. The simple parameter estimation method is also adopted to reduce deterioration of estimation of variables. The experimental results illustrate the validity of the analytical approach and the efficiency of the proposed method. | - |
| dc.language | 영어 | - |
| dc.language.iso | en | - |
| dc.publisher | IEEE | - |
| dc.title | A sensorless control using Extended Kalman Filter for an IPM synchronous motor based on an extended rotor flux | - |
| dc.type | Article | - |
| dc.contributor.affiliatedAuthor | Kim, Rae-Young | - |
| dc.identifier.doi | 10.1109/IECON.2012.6388731 | - |
| dc.identifier.scopusid | 2-s2.0-84872978588 | - |
| dc.identifier.bibliographicCitation | IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society, pp.1631 - 1636 | - |
| dc.relation.isPartOf | IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society | - |
| dc.citation.title | IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society | - |
| dc.citation.startPage | 1631 | - |
| dc.citation.endPage | 1636 | - |
| dc.type.rims | ART | - |
| dc.type.docType | Conference Paper | - |
| dc.description.journalClass | 1 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.subject.keywordPlus | Analytical approach | - |
| dc.subject.keywordPlus | Interior permanent magnet synchronous motor | - |
| dc.subject.keywordPlus | Parameter estimation method | - |
| dc.subject.keywordPlus | Parameters variations | - |
| dc.subject.keywordPlus | Random noise | - |
| dc.subject.keywordPlus | Rotor fluxes | - |
| dc.subject.keywordPlus | Sensor less control | - |
| dc.subject.keywordPlus | Sensorless drive method | - |
| dc.subject.keywordPlus | Sensorless drive systems | - |
| dc.subject.keywordPlus | Simple Parameter Estimation (SPE) | - |
| dc.subject.keywordPlus | Extended Kalman filters | - |
| dc.subject.keywordPlus | Industrial electronics | - |
| dc.subject.keywordPlus | Parameter estimation | - |
| dc.subject.keywordPlus | Synchronous motors | - |
| dc.subject.keywordPlus | Permanent magnets | - |
| dc.subject.keywordAuthor | Extended Kalman Filter (EKF) | - |
| dc.subject.keywordAuthor | Extended Rotor Flux (ERF) | - |
| dc.subject.keywordAuthor | Interior Permanent Magnet Synchronous Motors (IPMSMs) | - |
| dc.subject.keywordAuthor | Sensorless Control | - |
| dc.subject.keywordAuthor | Simple Parameter Estimation (SPE) | - |
| dc.identifier.url | https://ieeexplore.ieee.org/document/6388731 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.