Cited 0 time in
헤링본 마이크로 믹서를 이용한 폴리다이아세틸렌 센서 입자의 크기 제어 및 대량 합성
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 백성훈 | - |
| dc.contributor.author | 송시몬 | - |
| dc.date.accessioned | 2022-07-16T12:50:08Z | - |
| dc.date.available | 2022-07-16T12:50:08Z | - |
| dc.date.created | 2021-05-13 | - |
| dc.date.issued | 2012-11 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/164208 | - |
| dc.description.abstract | This study addresses a microfluidic approach for mass production and size-control of polydiacetylene (PDA) sensor vesicles using a staggered herringbone micromixer. The PDA is a conjugated polymer sensor with unique optical properties that show blue-to-red color transition and fluorescence emission by various stimulus such as pH changes, heat, and biochemical materials. We have shown that 2-D hydrodynamic focusing method (HDFM) can be applied to synthesize the size-controlled PDA vesicles. However, this method has a limitation that it is difficult to produce a large volume of PDA vesicles solution due to a limited flow rate and a clogging problem. Thus, we use a staggered herringbone micromixer (SHM), fabricated with inclined UV lithography developed by our group, to achieve a large volume of PDA vesicle solution with its size control by varying Reynolds number of the reaching flow. The size distribution of PDA vesicles is measured by dynamic light scattering. The results indicate that PDA vesicles are successfully synthesized using the micromixer and that the production volume can reach up to about 10 ㎖ for an hour while the 2-D HDFM resulted in only 0.24 ㎖. | - |
| dc.language | 한국어 | - |
| dc.language.iso | ko | - |
| dc.publisher | 대한기계학회 | - |
| dc.title | 헤링본 마이크로 믹서를 이용한 폴리다이아세틸렌 센서 입자의 크기 제어 및 대량 합성 | - |
| dc.title.alternative | Mass Production of Size-Controlled Polydiacetylene Sensor Vesicles Using a Staggered Herringbone Micromixer | - |
| dc.type | Article | - |
| dc.contributor.affiliatedAuthor | 송시몬 | - |
| dc.identifier.bibliographicCitation | 대한기계학회 2012년도 추계학술대회 논문집, pp.672 - 675 | - |
| dc.relation.isPartOf | 대한기계학회 2012년도 추계학술대회 논문집 | - |
| dc.citation.title | 대한기계학회 2012년도 추계학술대회 논문집 | - |
| dc.citation.startPage | 672 | - |
| dc.citation.endPage | 675 | - |
| dc.type.rims | ART | - |
| dc.type.docType | Proceeding | - |
| dc.description.journalClass | 3 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | other | - |
| dc.subject.keywordAuthor | Polydiacetylene sensor (폴리다이아세틸렌센서) | - |
| dc.subject.keywordAuthor | Mass production (대량합성) | - |
| dc.subject.keywordAuthor | Size control (크기 제어) | - |
| dc.subject.keywordAuthor | Staggered herringbone micromixer (교차 헤링본 마이크로믹서) | - |
| dc.identifier.url | https://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE02111703 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
