Cited 0 time in
강의실에서의 이산화탄소 농도 제어 방안 연구
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 김승범 | - |
| dc.contributor.author | 김주형 | - |
| dc.contributor.author | 김재준 | - |
| dc.date.accessioned | 2022-07-16T13:07:44Z | - |
| dc.date.available | 2022-07-16T13:07:44Z | - |
| dc.date.created | 2021-05-13 | - |
| dc.date.issued | 2012-10 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/164395 | - |
| dc.description.abstract | 24 hours a day, more than 80 percent of the city's day-to-day sent from the indoor space as you tend to seek emotional stability within the living space has increased. Due to the emphasis on traditional customs of Korea, kindergarten, elementary, junior high schools, special schools, colleges, universities, graduate schools, ranging from domestic total of 21,412 schools, with total of 11,440,205 students and teachers in more than half the time in the day are living in the interior. In this study, the number of schools number of students, compared to derive the concentration of carbon dioxide measured through the number of teachers with the highest percentage of college classrooms of the college classroom air quality problems, and derive a prediction equation based on the control of carbon dioxide measures to improve the indoor air environment improve the learning ability so that you can create a pleasant working environment, and propose an alternative. | - |
| dc.language | 한국어 | - |
| dc.language.iso | ko | - |
| dc.publisher | 한국건축친환경설비학회 | - |
| dc.title | 강의실에서의 이산화탄소 농도 제어 방안 연구 | - |
| dc.title.alternative | A Study on the CO2 Concentration Control in Lecture Room | - |
| dc.type | Article | - |
| dc.contributor.affiliatedAuthor | 김주형 | - |
| dc.contributor.affiliatedAuthor | 김재준 | - |
| dc.identifier.bibliographicCitation | 한국건축친환경설비학회 2012년도 추계학술발표대회, no. , pp.97 - 100 | - |
| dc.relation.isPartOf | 한국건축친환경설비학회 2012년도 추계학술발표대회 | - |
| dc.citation.title | 한국건축친환경설비학회 2012년도 추계학술발표대회 | - |
| dc.citation.startPage | 97 | - |
| dc.citation.endPage | 100 | - |
| dc.type.rims | ART | - |
| dc.type.docType | Proceeding | - |
| dc.description.journalClass | 3 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | other | - |
| dc.subject.keywordAuthor | 실내공기 | - |
| dc.subject.keywordAuthor | 강의실 | - |
| dc.subject.keywordAuthor | 이산화탄소 농도 | - |
| dc.subject.keywordAuthor | 식물 | - |
| dc.subject.keywordAuthor | 환기 | - |
| dc.subject.keywordAuthor | Indoor Air | - |
| dc.subject.keywordAuthor | Lecture Room | - |
| dc.subject.keywordAuthor | Carbon Dioxide | - |
| dc.subject.keywordAuthor | Plant | - |
| dc.subject.keywordAuthor | Ventilation | - |
| dc.identifier.url | https://www.auric.or.kr/User/Rdoc/DocRdoc.aspx?returnVal=RD_R&dn=290684#.YhQ5P-hBxPY | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
