Cited 0 time in
실험계획법을 이용한 Packed Tower 제습효율 예측모델에 관한 연구
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 박준영 | - |
| dc.contributor.author | 이은지 | - |
| dc.contributor.author | 김민휘 | - |
| dc.contributor.author | 정재원 | - |
| dc.date.accessioned | 2022-07-16T13:10:46Z | - |
| dc.date.available | 2022-07-16T13:10:46Z | - |
| dc.date.created | 2021-05-13 | - |
| dc.date.issued | 2012-10 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/164439 | - |
| dc.description.abstract | The main purpose of this research was to suggest packed tower dehumidification effectiveness correlations for liquid desiccant integrated system design and analysis. In this research, Liquid desiccant air conditioning system performance data produced using established literature reviews were statistically analyzed by design of experiments. The normal aqueous desiccant solutions; LiCl and TEG and common types of tower; packed tower, were analyzed. Suggested correlation relate to the packed bed tower dehumidification effectiveness as a function of five parameters; L/G(Liquid to gas ratio), inlet air and solution temperature, inlet air relative humidity, solution concentration. | - |
| dc.language | 한국어 | - |
| dc.language.iso | ko | - |
| dc.publisher | 한국건축친환경설비학회 | - |
| dc.title | 실험계획법을 이용한 Packed Tower 제습효율 예측모델에 관한 연구 | - |
| dc.title.alternative | A study on the propose of Packed tower dehumidification prediction model by using Design of Experiments | - |
| dc.type | Article | - |
| dc.contributor.affiliatedAuthor | 정재원 | - |
| dc.identifier.bibliographicCitation | 한국건축친환경설비학회 2012년도 추계학술발표대회, pp.45 - 48 | - |
| dc.relation.isPartOf | 한국건축친환경설비학회 2012년도 추계학술발표대회 | - |
| dc.citation.title | 한국건축친환경설비학회 2012년도 추계학술발표대회 | - |
| dc.citation.startPage | 45 | - |
| dc.citation.endPage | 48 | - |
| dc.type.rims | ART | - |
| dc.type.docType | Proceeding | - |
| dc.description.journalClass | 3 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | other | - |
| dc.subject.keywordAuthor | 액체식 제습기 | - |
| dc.subject.keywordAuthor | 충진탑식 제습기 | - |
| dc.subject.keywordAuthor | 제습효율 | - |
| dc.subject.keywordAuthor | 모델링 | - |
| dc.subject.keywordAuthor | 제습 공조 | - |
| dc.subject.keywordAuthor | Liquid desiccant | - |
| dc.subject.keywordAuthor | Packed bed Tower | - |
| dc.subject.keywordAuthor | Dehumidification effectiveness | - |
| dc.subject.keywordAuthor | Modelling | - |
| dc.subject.keywordAuthor | Desiccant air conditioning | - |
| dc.identifier.url | https://www.auric.or.kr/User/Rdoc/DocRdoc.aspx?returnVal=RD_R&dn=290670#.YhQ5z-hBxPY | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
