Cited 0 time in
태양광 시스템을 위한 가변 조정계수 기반의 적응형 MPPT 제어 기법
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 이귀준 | - |
| dc.contributor.author | 김래영 | - |
| dc.contributor.author | 현동석 | - |
| dc.contributor.author | 임춘호 | - |
| dc.contributor.author | 김우철 | - |
| dc.date.accessioned | 2022-07-16T13:22:35Z | - |
| dc.date.available | 2022-07-16T13:22:35Z | - |
| dc.date.created | 2021-05-13 | - |
| dc.date.issued | 2012-10 | - |
| dc.identifier.issn | 1229-2214 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/164473 | - |
| dc.description.abstract | An adaptive maximum power point tracking (MPPT) scheme employing a variable scaling factor is presented. A MPPT control loop was constructed analytically and the magnitude variation in the MPPT loop gain according to the operating point of the PV array was identified due to the nonlinear characteristics of the PV array output. To make the crossover frequency of the MPPT loop gain consistent, the variable scaling factor was determined using an approximate curve-fitted polynomial equation about linear expression of the error. Therefore, a desirable dynamic response and the stability of the MPPT scheme were maintained across the entire MPPT voltage range. The simulation and experimental results obtained from a 3 KW rated prototype demonstrated the effectiveness of the proposed MPPT scheme. | - |
| dc.language | 한국어 | - |
| dc.language.iso | ko | - |
| dc.publisher | 전력전자학회 | - |
| dc.title | 태양광 시스템을 위한 가변 조정계수 기반의 적응형 MPPT 제어 기법 | - |
| dc.title.alternative | An Adaptive Maximum Power Point Tracking Scheme Based on a Variable Scaling Factor for Photovoltaic Systems | - |
| dc.type | Article | - |
| dc.contributor.affiliatedAuthor | 김래영 | - |
| dc.identifier.doi | 10.6113/TKPE.2012.17.5.423 | - |
| dc.identifier.bibliographicCitation | 전력전자학회 논문지, v.17, no.5, pp.423 - 430 | - |
| dc.relation.isPartOf | 전력전자학회 논문지 | - |
| dc.citation.title | 전력전자학회 논문지 | - |
| dc.citation.volume | 17 | - |
| dc.citation.number | 5 | - |
| dc.citation.startPage | 423 | - |
| dc.citation.endPage | 430 | - |
| dc.type.rims | ART | - |
| dc.identifier.kciid | ART001705049 | - |
| dc.description.journalClass | 2 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | maximum power point tracking (MPPT) | - |
| dc.subject.keywordAuthor | photovoltaic (PV) | - |
| dc.subject.keywordAuthor | scaling factor | - |
| dc.subject.keywordAuthor | small-signal model | - |
| dc.subject.keywordAuthor | curve fitting | - |
| dc.identifier.url | http://koreascience.or.kr/article/JAKO201231434108276.page | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
