A new computerized diagnostic algorithm for quantitative evaluation of binocular misalignment in patients with strabismus

Full metadata record
DC Field Value Language
dc.contributor.authorNam, Kyoung Won-
dc.contributor.authorKim, In Young-
dc.contributor.authorKang, Ho Chul-
dc.contributor.authorYang, Hee Kyung-
dc.contributor.authorYoon, Chang Ki-
dc.contributor.authorHwang, Jeong Min-
dc.contributor.authorKim, Young Jae-
dc.contributor.authorKim, Tae Yun-
dc.contributor.authorKim, Kwang Gi-
dc.date.accessioned2022-07-16T13:27:34Z-
dc.date.available2022-07-16T13:27:34Z-
dc.date.created2021-05-12-
dc.date.issued2012-10-
dc.identifier.issn0374-4884-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/164536-
dc.description.abstractAccurate measurement of binocular misalignment between both eyes is important for proper preoperative management, surgical planning, and postoperative evaluation of patients with strabismus. In this study, we proposed a new computerized diagnostic algorithm that can calculate the angle of binocular eye misalignment photographically by using a dedicated three-dimensional eye model mimicking the structure of the natural human eye. To evaluate the performance of the proposed algorithm, eight healthy volunteers and eight individuals with strabismus were recruited in this study, the horizontal deviation angle, vertical deviation angle, and angle of eye misalignment were calculated and the angular differences between the healthy and the strabismus groups were evaluated using the nonparametric Mann-Whitney test and the Pearson correlation test. The experimental results demonstrated a statistically significant difference between the healthy and strabismus groups (p = 0.015 < 0.05), but no statistically significant difference between the proposed method and the Krimsky test (p = 0.912 > 0.05). The measurements of the two methods were highly correlated (r = 0.969, p < 0.05). From the experimental results, we believe that the proposed diagnostic method has the potential to be a diagnostic tool that measures the physical disorder of the human eye to diagnose non-invasively the severity of strabismus.-
dc.language영어-
dc.language.isoen-
dc.publisherKOREAN PHYSICAL SOC-
dc.titleA new computerized diagnostic algorithm for quantitative evaluation of binocular misalignment in patients with strabismus-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, In Young-
dc.identifier.doi10.3938/jkps.61.1114-
dc.identifier.scopusid2-s2.0-84867440106-
dc.identifier.wosid000309867000024-
dc.identifier.bibliographicCitationJOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.61, no.7, pp.1114 - 1119-
dc.relation.isPartOfJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.citation.titleJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.citation.volume61-
dc.citation.number7-
dc.citation.startPage1114-
dc.citation.endPage1119-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.identifier.kciidART001705703-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryPhysics, Multidisciplinary-
dc.subject.keywordPlusPURKINJE I-
dc.subject.keywordPlusHIRSCHBERG-
dc.subject.keywordAuthorBody disorder-
dc.subject.keywordAuthorStrabismus-
dc.subject.keywordAuthorComputerized diagnosis-
dc.identifier.urlhttps://link.springer.com/article/10.3938%2Fjkps.61.1114-
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 의공학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, In Young photo

Kim, In Young
COLLEGE OF MEDICINE (DEPARTMENT OF BIOMEDICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE