Cited 0 time in
부갑상선 기능 항진증에서 병변의 영상학적 진단과 위치 탐색 방법의 비교 연구
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 성의숙 | - |
| dc.contributor.author | 지용배 | - |
| dc.contributor.author | 최윤영 | - |
| dc.contributor.author | 김지영 | - |
| dc.contributor.author | 박정선 | - |
| dc.contributor.author | 이영준 | - |
| dc.contributor.author | 태경 | - |
| dc.date.accessioned | 2022-07-16T13:47:55Z | - |
| dc.date.available | 2022-07-16T13:47:55Z | - |
| dc.date.issued | 2012-09 | - |
| dc.identifier.issn | 2092-5859 | - |
| dc.identifier.issn | 2092-6529 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/164700 | - |
| dc.description.abstract | Background and Objectives Accurate preoperative localization of abnormal parathyroid gland is essential for successful parathyroidectomy. The aim of this study was to evaluate the accuracy of a localization test for hyperparathyroidism including ultrasonography (US), computed tomography (CT) and 99mTc-sestamibi scan. Subjects and Method We studied 47 patients with hyperparathyroidism who underwent parathyroidectomy from January 2003 through December 2010, retrospectively. 99mTc-sestamibi scan, US and CT were carried out as a preoperative localization test and their accuracy were analyzed according to the size, location and pathology of parathyroid lesions. Results The accuracy of 99mTc-sestamibi scan, US and CT were 93%, 77% and 65%, respectively. The accuracy of 99mTc-sestamibi scan and CT combined was 94% and US and CT 73%. The accuracy of combination of US and 99mTc-sestamibi scan was 96%, which was not different depending on size, location and pathology of parathyroid lesions. Conclusion The combination of 99mTc-sestamibi scan and US is the most effective method for preoperative detection and the localization of hyperparathyroidism. | - |
| dc.format.extent | 6 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 대한이비인후과학회 | - |
| dc.title | 부갑상선 기능 항진증에서 병변의 영상학적 진단과 위치 탐색 방법의 비교 연구 | - |
| dc.title.alternative | Comparative Study of Preoperative Imaging Detection and Localization Test for Hyperparathyroidism | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.3342/kjorl-hns.2012.55.9.565 | - |
| dc.identifier.bibliographicCitation | 대한이비인후-두경부외과학회지, v.55, no.9, pp 565 - 570 | - |
| dc.citation.title | 대한이비인후-두경부외과학회지 | - |
| dc.citation.volume | 55 | - |
| dc.citation.number | 9 | - |
| dc.citation.startPage | 565 | - |
| dc.citation.endPage | 570 | - |
| dc.identifier.kciid | ART001695701 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Hyperparathyroidism | - |
| dc.subject.keywordAuthor | Localization | - |
| dc.subject.keywordAuthor | Parathyroidectomy | - |
| dc.subject.keywordAuthor | Ultrasonography | - |
| dc.subject.keywordAuthor | 99mTc-sestamibi scan | - |
| dc.identifier.url | https://www.kjorl.org/journal/view.php?doi=10.3342/kjorl-hns.2012.55.9.565 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
