dc.description.abstractThe paper presents an experimental study on the behavior of square concrete-filled high strength steel tube columns until failure. Four specimens were tested to investigate the effect of high strength steel and plain strength concrete on the load carrying capacity of the square concrete-filled steel tube columns. The effect of the concrete which filled in the steel tube was also investigated. Also, the effect of high strength steel and the presence of concrete were also investigated. The main parameters in the tests were: (1) the ultimate strength of steel (800 MPa), (2) the presence of concrete in steel tube (hollow steel tube and concrete-filled steel tube), and (3) slender ratio. The main objectives of these tests were three-step: (1) to describe a series of tests on composite columns, (2) to analyze the influence of several parameters, and (3) to compare the accuracy of the predictions by using the specifications in the code (AISC-LRFD, EC4 and AIJ etc.) for the design of high-strength composite columns. Experimental results indicate that the ultimate strength of steel and presence of concrete had significant influence on both the axial compressive load capacity and the ductile of the square steel tube.-
dc.language영어-
dc.language.isoen-
dc.publisherAmerican Scientific Publishers-
dc.titleThe behavior of high-strength square steel tube columns filled with concrete-
dc.typeArticle-
dc.contributor.affiliatedAuthorChoi, Chang Sik-
dc.identifier.doi10.1166/asl.2012.3899-
dc.identifier.scopusid2-s2.0-84863327379-
dc.identifier.bibliographicCitationAdvanced Science Letters, v.13, no.1, pp.146 - 151-
dc.relation.isPartOfAdvanced Science Letters-
dc.citation.titleAdvanced Science Letters-
dc.citation.volume13-
dc.citation.number1-
dc.citation.startPage146-
dc.citation.endPage151-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscopus-
dc.subject.keywordAuthorAxial compression-
dc.subject.keywordAuthorHigh strength steel-
dc.subject.keywordAuthorSquare concrete-filled steel tube column-
dc.identifier.urlhttps://www.ingentaconnect.com/content/asp/asl/2012/00000013/00000001/art00024-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 건축공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Choi, Chang Sik photo

Choi, Chang Sik
COLLEGE OF ENGINEERING (SCHOOL OF ARCHITECTURAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE