Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Spirally oriented Au microelectrode array sensor for detection of Hg (II)

Full metadata record
DC Field Value Language
dc.contributor.authorTran Ngoc Huan-
dc.contributor.authorLe Quoc Hung-
dc.contributor.authorVu Thi Thu Ha-
dc.contributor.authorNguyen Hoang Anh-
dc.contributor.authorTran Van Khai-
dc.contributor.authorShim, Kwang Bo-
dc.contributor.authorChung, Hoeil-
dc.date.accessioned2022-07-16T15:46:00Z-
dc.date.available2022-07-16T15:46:00Z-
dc.date.created2021-05-12-
dc.date.issued2012-05-
dc.identifier.issn0039-9140-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/165743-
dc.description.abstractA simple and reproducible carbon microelectrode array (CMA), designed to eliminate diffusive interference among the microelectrodes, has been fabricated and used as a frame to build a gold (Au) microelectrode array (GMA) sensor. To prepare the CMA initially, rather than use an uncontrollable large number of carbon fibers, only 60 carbon fibers of regular size were used to ensure manageable and reproducible arrangement for array construction. In addition, for efficient spatial arrangement of the microelectrode and easy sensor preparation, carbon fibers were oriented in a spiral fashion by rolling around a Cu wire. The distance between carbon fibers was carefully determined to avoid overlap among individual diffusion layers, one of the important factors governing steady-state current response and sensor-to-sensor reproducibility. After the preparation of a spirally arranged CMA, Au was electrochemically deposited on the surface of individual carbon electrodes to build a final GMA sensor. Then, the GMA sensor was used to measure Hg2+ in a low concentration range. Simultaneously, multiple GMA sensors were independently prepared to examine reproducibility in sensor fabrication as well as electrochemical measurement (sensor-to-sensor reproducibility). Overall, highly sensitive detection of Hg2+ was possible using the proposed GMA sensor due to efficient arrangement of microelectrodes and the sensor-to-sensor reproducibility was superior owing to simplicity in sensor fabrication.-
dc.language영어-
dc.language.isoen-
dc.publisherELSEVIER-
dc.titleSpirally oriented Au microelectrode array sensor for detection of Hg (II)-
dc.typeArticle-
dc.contributor.affiliatedAuthorChung, Hoeil-
dc.identifier.doi10.1016/j.talanta.2012.03.041-
dc.identifier.scopusid2-s2.0-84861226740-
dc.identifier.wosid000305167300043-
dc.identifier.bibliographicCitationTALANTA, v.94, pp.284 - 288-
dc.relation.isPartOfTALANTA-
dc.citation.titleTALANTA-
dc.citation.volume94-
dc.citation.startPage284-
dc.citation.endPage288-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.subject.keywordPlusELECTRODES-
dc.subject.keywordPlusVOLTAMMETRY-
dc.subject.keywordPlusMERCURY-
dc.subject.keywordAuthorMicroelectrode array sensor-
dc.subject.keywordAuthorCarbon fiber-
dc.subject.keywordAuthorGold microelectrode-
dc.subject.keywordAuthorMercury detection-
dc.subject.keywordAuthorDiffusive interference-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S003991401200269X?via%3Dihub-
Files in This Item
Go to Link
Appears in
Collections
서울 자연과학대학 > 서울 화학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Chung, Hoeil photo

Chung, Hoeil
COLLEGE OF NATURAL SCIENCES (DEPARTMENT OF CHEMISTRY)
Read more

Altmetrics

Total Views & Downloads

BROWSE