Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Paired pulse voltammetry for differentiating complex analytes

Authors
Jang, Dong PyoKim, InyongChang, Su-YouneMin, Hoon-KiArora, KanikaMarsh, Michale P.Hwang, Sun-ChulKimble, Christopher J.Bennet, Kevin E.Lee, Kendall H.
Issue Date
Mar-2012
Publisher
Royal Society of Chemistry
Citation
Analyst, v.137, no.6, pp 1428 - 1435
Pages
8
Indexed
SCI
SCIE
SCOPUS
Journal Title
Analyst
Volume
137
Number
6
Start Page
1428
End Page
1435
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/166097
DOI
10.1039/c2an15912k
ISSN
0003-2654
1364-5528
Abstract
Although fast-scan cyclic voltammetry (FSCV) has contributed to important advances in neuroscience research, the technique is encumbered by significant analytical challenges. Confounding factors such as pH change and transient effects at the microelectrode surface make it difficult to discern the analytes represented by complex voltammograms. Here we introduce paired-pulse voltammetry (PPV), that mitigates the confounding factors and simplifies the analytical task. PPV consists of a selected binary waveform with a specific time gap between each of its two comprising pulses, such that each binary wave is repeated, while holding the electrode at a negative potential between the waves. This allows two simultaneous yet very different voltammograms (primary and secondary) to be obtained, each corresponding to the two pulses in the binary waveform. PPV was evaluated in the flow cell to characterize three different analytes, (dopamine, adenosine, and pH changes). The peak oxidation current decreased by approximately 50%, 80%, and 4% for dopamine, adenosine, and pH, in the secondary voltammogram compared with the primary voltammogram, respectively. Thus, the influence of pH changes could be virtually eliminated using the difference between the primary and secondary voltammograms in the PPV technique, which discriminates analytes on the basis of their adsorption characteristics to the carbon fiber electrode. These results demonstrate that PPV can be effectively used for differentiating complex analytes.
Files in This Item
There are no files associated with this item.
Appears in
Collections
서울 의생명공학전문대학원 > ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jang, Dong Pyo photo

Jang, Dong Pyo
GRADUATE SCHOOL OF BIOMEDICAL SCIENCE AND ENGINEERING (서울 생체의공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE