Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Gamma electron vertex imaging and application to beam range verification in proton therapy

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Chan Hyeong-
dc.contributor.authorPark, Jin Hyung-
dc.contributor.authorSeo, Hee-
dc.contributor.authorLee, Han Rim-
dc.date.accessioned2022-07-16T16:50:18Z-
dc.date.available2022-07-16T16:50:18Z-
dc.date.created2021-05-12-
dc.date.issued2012-02-
dc.identifier.issn0094-2405-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/166368-
dc.description.abstractPurpose: This paper describes a new gamma-ray imaging method, "gamma electron vertex imaging (GEVI)," which can be used for precise beam range verification in proton therapy. Methods: In GEVI imaging, the high-energy gammas from a source or nuclear interactions are first converted, by Compton scattering, to electrons, which subsequently are traced by hodoscopes to determine the location of the gamma source or the vertices of the nuclear interactions. The performance of GEVI imaging for use in-beam range verification was evaluated by Monte Carlo simulations employing GEANT4 equipped with the QGSP_BIC_HP physics package. Results: Our simulation results show that GEVI imaging can determine the proton beam range very accurately, within 2-3 mm of error, even without any sophisticated analysis. The results were obtained under simplified conditions of monoenergetic pencil beams stopped in a homogeneous phantom and on the basis of the obtained results it is expected to achieve submillimeter accuracy in proton beam range measurement. Conclusions: If future experimental work confirms the simulated results presented in this paper, the use of GEVI imaging is expected to have a great potential in increasing the accuracy of proton beam range verification in a patient, resulting in significant improvement of treatment effectiveness by enabling tight conformation of radiation dose to the tumor volume and patient safety. (C) 2012 American Association of Physicists in Medicine.-
dc.language영어-
dc.language.isoen-
dc.publisherAMER ASSOC PHYSICISTS MEDICINE AMER INST PHYSICS-
dc.titleGamma electron vertex imaging and application to beam range verification in proton therapy-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Chan Hyeong-
dc.identifier.doi10.1118/1.3662890-
dc.identifier.scopusid2-s2.0-84856976676-
dc.identifier.wosid000300215800045-
dc.identifier.bibliographicCitationMEDICAL PHYSICS, v.39, no.2, pp.1001 - 1005-
dc.relation.isPartOfMEDICAL PHYSICS-
dc.citation.titleMEDICAL PHYSICS-
dc.citation.volume39-
dc.citation.number2-
dc.citation.startPage1001-
dc.citation.endPage1005-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordPlusRAY TELESCOPES-
dc.subject.keywordPlusCAMERA-
dc.subject.keywordPlusDETECTOR-
dc.subject.keywordAuthorproton therapy-
dc.subject.keywordAuthorprompt gamma-
dc.subject.keywordAuthorrange verification-
dc.subject.keywordAuthorgamma electron vertex imaging-
dc.identifier.urlhttps://aapm.onlinelibrary.wiley.com/doi/full/10.1118/1.3662890-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE