Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Mallampati 분류 1 또는 2의 환자에서 Pentax AWS, Glidescope, Macintosh laryngoscope를 이용한 기관삽관의 비교연구

Full metadata record
DC Field Value Language
dc.contributor.author정지선-
dc.contributor.author정미애-
dc.contributor.author조주원-
dc.contributor.author조재현-
dc.contributor.author심재항-
dc.contributor.author서정국-
dc.date.accessioned2022-07-16T16:59:32Z-
dc.date.available2022-07-16T16:59:32Z-
dc.date.created2021-05-13-
dc.date.issued2012-01-
dc.identifier.issn1975-5171-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/166466-
dc.description.abstractBackground: The Pentax AWS and the Glidescope are new intubating devices. They were designed to provide a view of the glottis without alignment of the oral, pharyngeal and tracheal axis. The purpose of this study was to evaluate the effectiveness of the Pentax AWS and the Glidescope in comparison with the Macintosh laryngoscope, when performing tracheal intubation in patients with mallampati classification I or II. Methods: Ninety patients presenting for surgery requiring tracheal intubation, and who were deemed easy for tracheal intubation of mallampati classification I or II were randomly assigned to undergo intubation using a Macintosh (Group M, n = 30), Pentax AWS (Group P, n = 30) or Glidescope (Group G, n = 30). Time to complete tracheal intubation and number of attempts until successful intubation were recorded. Noninvasive blood pressure and heart rate recorded before induction (PI), just before intubation (PT), 1 min and 5 min after intubation. Patients were assessed for postoperative sore throat at 6−12 h after surgery. Results: Time to secure the airway with the Macintosh 13.0 (min 7, max 23.0) s was lesser than with the Pentax AWS 20.4 (8, 51.2)s and Glidescope 22.1 (10, 42.0) s. There were no significant differences in the rate of successful intubations and sore throat among the groups. There were significant increases in both mean arterial pressure and heart rate 1 min after intubation in all groups compare with PI. Conclusions: The Pentax AWS and the Glidescope had no specific advantage over the Macintosh laryngoscope for the patients with normal airway.-
dc.language한국어-
dc.language.isoko-
dc.publisher대한마취통증의학회-
dc.titleMallampati 분류 1 또는 2의 환자에서 Pentax AWS, Glidescope, Macintosh laryngoscope를 이용한 기관삽관의 비교연구-
dc.title.alternativeComparison of the Pentax AWS and the Glidescope with the Macintosh laryngoscope for tracheal intubation in patients with Mallampati classification I or II-
dc.typeArticle-
dc.contributor.affiliatedAuthor정미애-
dc.identifier.bibliographicCitationAnesthesia and Pain Medicine, v.7, no.1, pp.91 - 96-
dc.relation.isPartOfAnesthesia and Pain Medicine-
dc.citation.titleAnesthesia and Pain Medicine-
dc.citation.volume7-
dc.citation.number1-
dc.citation.startPage91-
dc.citation.endPage96-
dc.type.rimsART-
dc.identifier.kciidART001628230-
dc.description.journalClass2-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasskci-
dc.description.journalRegisteredClassother-
dc.subject.keywordAuthorHemodynamic response-
dc.subject.keywordAuthorIntubation time-
dc.subject.keywordAuthorMacintosh laryngoscope-
dc.subject.keywordAuthorVideo laryngoscope.-
dc.identifier.urlhttps://www.anesth-pain-med.org/journal/view.php?number=525-
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 마취통증의학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jeong, Mi Ae photo

Jeong, Mi Ae
COLLEGE OF MEDICINE (DEPARTMENT OF ANESTHESIA AND MEDICINE)
Read more

Altmetrics

Total Views & Downloads

BROWSE