| dc.description.abstract | For the design of a MEMS accelerometer, proper performance indices should be defined and employed. Performance indices are obtained using either an experimental method or a numerical method. In the present study, a vibration analysis model of a MEMS accelerometer is introduced to calculate three performance indices: sensitivity, measurable acceleration range, and measurable frequency range. The accuracy of the vibration analysis model is first validated by comparing its modal and transient results with those of a commercial finite element code. Measurable acceleration and frequency ranges versus allowable errors for electrical and mechanical sensitivities are obtained and the effects of system parameter variations on the three performance indices are investigated. | - |
| dc.format.extent | 7 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | 대한기계학회 | - |
| dc.title | Development of multiple performance indices and system parameter study for the design of a MEMS accelerometer | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.1007/s12206-011-1205-2 | - |
| dc.identifier.scopusid | 2-s2.0-84862922862 | - |
| dc.identifier.wosid | 000299012800004 | - |
| dc.identifier.bibliographicCitation | Journal of Mechanical Science and Technology, v.26, no.1, pp 31 - 37 | - |
| dc.citation.title | Journal of Mechanical Science and Technology | - |
| dc.citation.volume | 26 | - |
| dc.citation.number | 1 | - |
| dc.citation.startPage | 31 | - |
| dc.citation.endPage | 37 | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART001618676 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Mechanical | - |
| dc.subject.keywordPlus | Accelerometers | - |
| dc.subject.keywordPlus | Finite element method | - |
| dc.subject.keywordPlus | MEMS | - |
| dc.subject.keywordPlus | Numerical methods | - |
| dc.subject.keywordPlus | Optimal systems | - |
| dc.subject.keywordPlus | Sensitivity analysis | - |
| dc.subject.keywordPlus | Commercial finite element codes | - |
| dc.subject.keywordPlus | Experimental methods | - |
| dc.subject.keywordPlus | Frequency ranges | - |
| dc.subject.keywordPlus | Measurable acceleration range | - |
| dc.subject.keywordPlus | Mechanical sensitivity | - |
| dc.subject.keywordPlus | MEMS accelerometer | - |
| dc.subject.keywordPlus | Parameter studies | - |
| dc.subject.keywordPlus | Parameter variation | - |
| dc.subject.keywordPlus | Performance indices | - |
| dc.subject.keywordPlus | Vibration analysis | - |
| dc.subject.keywordAuthor | Measurable acceleration range | - |
| dc.subject.keywordAuthor | Measurable frequency range | - |
| dc.subject.keywordAuthor | MEMS | - |
| dc.subject.keywordAuthor | Vibration analysis model | - |
| dc.identifier.url | https://link.springer.com/article/10.1007%2Fs12206-011-1205-2 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.