무지 외반증 각변형에 대한 디지털영상의 전산화 계측: 100%와 150% 확대영상에서의 계측비교

Full metadata record
DC Field Value Language
dc.contributor.author성일훈-
dc.contributor.author이두연-
dc.contributor.author성창호-
dc.contributor.author서우영-
dc.date.accessioned2022-07-16T17:26:52Z-
dc.date.available2022-07-16T17:26:52Z-
dc.date.created2021-05-13-
dc.date.issued2012-
dc.identifier.issn1738-3757-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/166658-
dc.description.abstractPurpose: To study computerized measurements of angular parameters on 100% and 150% resized digital radiography of hallux valgus deformity Materials and Methods: 30 digital radiography of standing foot anteroposterior view of hallux valgus patients were included. Two observers(A, B) independently measured hallux valgus angle (HVA), 1-2 intermetatarsal angle (IMA), and distal metatarsal articular angle (DMAA) in two times on both 100%-size and 150% magnified images respectively, using computerized measurement software tools. The results were interpreted with the statistical software program, Statistical Analysis System, version 9.2. Results: In repeated measurements of each observer, measurements on 150% magnified image showed no differences of all three parameters and with 100%-size image, there were differences of HVA (observer A) and 1-2 IMA (observer B) (p>0.05). When testing interobserver reliability, both observers showed differences in measurement of HVA and DMAA (p<0.05), but no differences in measurement of 1-2 IMA in both images. Within the 95% confidence interval, limits of error of measurements between two observers on HVA, IMA and DMAA were 2.7° 1.4° and 5.0° respectively in 100%-size images, and 2.6°, 1.6° and 4.7° respectively in 150% magnified images. Conclusion: In computerized measurements for angular parameters of hallux valgus with digital radiography, 150% magnified images showed intraobserver reliability. Both 100% and 150% magnified images failed to show interobserver reliability. Measurement of 1-2 IMA in both 100% and 150% images showed less interobserver error.-
dc.language한국어-
dc.language.isoko-
dc.publisher대한족부족관절학회-
dc.title무지 외반증 각변형에 대한 디지털영상의 전산화 계측: 100%와 150% 확대영상에서의 계측비교-
dc.title.alternativeComputerized Measurement on Angular Parameters for Hallux Valgus: Comparison of 100% and 150% Magnified Digital Radiography-
dc.typeArticle-
dc.contributor.affiliatedAuthor성일훈-
dc.identifier.bibliographicCitation대한족부족관절학회지, v.16, no.1, pp.53 - 57-
dc.relation.isPartOf대한족부족관절학회지-
dc.citation.title대한족부족관절학회지-
dc.citation.volume16-
dc.citation.number1-
dc.citation.startPage53-
dc.citation.endPage57-
dc.type.rimsART-
dc.identifier.kciidART001642225-
dc.description.journalClass2-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasskci-
dc.description.journalRegisteredClassother-
dc.subject.keywordAuthorHallux valgus-
dc.subject.keywordAuthorAngular parameters-
dc.subject.keywordAuthorComputerized measurement-
dc.identifier.urlhttps://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART001642225-
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 정형외과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher SUNG, IL HOON photo

SUNG, IL HOON
COLLEGE OF MEDICINE (DEPARTMENT OF ORTHOPEDIC SURGERY)
Read more

Altmetrics

Total Views & Downloads

BROWSE