Cited 0 time in
제주 HVDC#3 영향 분석
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 박정수 | - |
| dc.contributor.author | 정홍주 | - |
| dc.contributor.author | 한영성 | - |
| dc.contributor.author | 김래영 | - |
| dc.contributor.author | 정정주 | - |
| dc.date.accessioned | 2022-07-16T17:37:54Z | - |
| dc.date.available | 2022-07-16T17:37:54Z | - |
| dc.date.issued | 2011-12 | - |
| dc.identifier.issn | 1975-8359 | - |
| dc.identifier.issn | 2287-4364 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/166797 | - |
| dc.description.abstract | According to the 5th national plan for electric power demand and supply, the 3rd HVDC link will be installed between KEPCO and Jeju Island system and go into operation in June, 2016. However, if it adopt LCC HVDC,Jeju power system could be in voltage instable condition. In order to solve the problem, we propose the application of VSC HVDC to the 3rd HVDC project. In the past, VSC HVDC has many disadvantages such as, inefficiency in conversion, size limit, and expensiveness, compared to LCC HVDC. Recently, the new technologies and the demand for renewable energy interconnection are leading a large growth in VSC HVDC market. In this paper, we will introduce the technical and market trends of VSC HVDC and power system stability analysis results for Jeju power system having LCC and VSC HVDCs. | - |
| dc.format.extent | 6 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 대한전기학회 | - |
| dc.title | 제주 HVDC#3 영향 분석 | - |
| dc.title.alternative | The Effect of HVDC#3 on Jeju Power System | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.5370/KIEE.2011.60.12.2196 | - |
| dc.identifier.scopusid | 2-s2.0-83755196784 | - |
| dc.identifier.bibliographicCitation | 전기학회논문지, v.60, no.12, pp 2196 - 2201 | - |
| dc.citation.title | 전기학회논문지 | - |
| dc.citation.volume | 60 | - |
| dc.citation.number | 12 | - |
| dc.citation.startPage | 2196 | - |
| dc.citation.endPage | 2201 | - |
| dc.identifier.kciid | ART001605814 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordPlus | Commerce | - |
| dc.subject.keywordPlus | DC power transmission | - |
| dc.subject.keywordPlus | HVDC power transmission | - |
| dc.subject.keywordPlus | System stability | - |
| dc.subject.keywordPlus | Electric power system planning | - |
| dc.subject.keywordPlus | Electric power demands | - |
| dc.subject.keywordPlus | Jeju island | - |
| dc.subject.keywordPlus | Jeju power system | - |
| dc.subject.keywordPlus | LCC HVDC | - |
| dc.subject.keywordPlus | Market trends | - |
| dc.subject.keywordPlus | Power system stability | - |
| dc.subject.keywordPlus | Renewable energies | - |
| dc.subject.keywordPlus | VSC-HVDC | - |
| dc.subject.keywordAuthor | Power system stability | - |
| dc.subject.keywordAuthor | LCC HVDC | - |
| dc.subject.keywordAuthor | VSC HVDC | - |
| dc.identifier.url | https://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE01736940 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.