| dc.description.abstract | The wind response and performance of a tuned mass damper (TMD) are presented based on the system identification and the inverse wind load estimation. The TMD was installed on a 39-story, 184.6m steel building located in Incheon, Korea with a monitoring system consisting of an anemometer, accelerometers, and internet-based data logging system. On Sep. 2, 2010, the building experienced the Kompasu Typhoon, in which the peak wind speed, measured by an anemometer installed on the roof floor, was 49.7 m/s. In order to analyze the behavior of the building during the typhoon, the dynamic properties of building and TMD are identified from the measured responses. The modal wind load is then inversely estimated from the TMD and building accelerations using a Kalman filter, and the vibration reduction performance of the TMD is evaluated. | - |
| dc.language | 한국어 | - |
| dc.language.iso | ko | - |
| dc.publisher | 대한건축학회 | - |
| dc.title | TMD가 설치된 구조물의 태풍거동 분석 | - |
| dc.title.alternative | Wind Response Monitoring of a Building with TMD | - |
| dc.type | Article | - |
| dc.contributor.affiliatedAuthor | 유은종 | - |
| dc.identifier.bibliographicCitation | 대한건축학회논문집 구조계, v.27, no.12, pp.83 - 90 | - |
| dc.relation.isPartOf | 대한건축학회논문집 구조계 | - |
| dc.citation.title | 대한건축학회논문집 구조계 | - |
| dc.citation.volume | 27 | - |
| dc.citation.number | 12 | - |
| dc.citation.startPage | 83 | - |
| dc.citation.endPage | 90 | - |
| dc.type.rims | ART | - |
| dc.identifier.kciid | ART001621492 | - |
| dc.description.journalClass | 2 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Tuned Mass Damper | - |
| dc.subject.keywordAuthor | Wind-induced Vibration | - |
| dc.subject.keywordAuthor | System Identification | - |
| dc.subject.keywordAuthor | Inverse Load Estimation | - |
| dc.subject.keywordAuthor | 동조질량감쇠기 | - |
| dc.subject.keywordAuthor | 풍진동 | - |
| dc.subject.keywordAuthor | 시스템식별 | - |
| dc.subject.keywordAuthor | 하중역추정 | - |
| dc.identifier.url | https://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE01759308 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.