dc.description.abstract | The propose of this study is to evaluate the rotation capacity of Welded Unreinforced Flange-Welded web moment connections detailed in compliance with ANSI/AISC 358. In this study, four full-scale one-sided test specimens were made and quasi-static cyclic testing was conducted. The variables of test specimens are the effects of beam depth and strength ratio between beam and panel zone on plastic rotation capacity of WUF-W moment connection. From the test results, it was found that test specimens having deep beam fractured in the beam flange before achieving total interstory drift angle of 0.04 radian required for Special Moment Frames system in ANSI/AISC-341, while shallow beam specimens performed well, achieving total interstory drift angle of at least 0.04 radians. | - |
dc.language | 한국어 | - |
dc.language.iso | ko | - |
dc.publisher | 대한건축학회 | - |
dc.title | WUF-W 접합부의 반복 하중 실험을 통한 회전성능 평가 | - |
dc.title.alternative | Evaluation rotation capacity of WUF-W connections according to cyclic loading tests | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | 한상환 | - |
dc.identifier.bibliographicCitation | 대한건축학회 추계학술발표대회논문집 구조계, v.31, no.2, pp.215 - 216 | - |
dc.relation.isPartOf | 대한건축학회 추계학술발표대회논문집 구조계 | - |
dc.citation.title | 대한건축학회 추계학술발표대회논문집 구조계 | - |
dc.citation.volume | 31 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 215 | - |
dc.citation.endPage | 216 | - |
dc.type.rims | ART | - |
dc.type.docType | Proceeding | - |
dc.description.journalClass | 2 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | other | - |
dc.subject.keywordAuthor | WUF-W 접합부 | - |
dc.subject.keywordAuthor | 특수모멘트골조 | - |
dc.subject.keywordAuthor | 반복하중실험 | - |
dc.subject.keywordAuthor | 접합부회전성능 | - |
dc.subject.keywordAuthor | WUF-W connections | - |
dc.subject.keywordAuthor | Special moment frame | - |
dc.subject.keywordAuthor | Cyclic loading test | - |
dc.subject.keywordAuthor | Connection rotation capacity | - |
dc.identifier.url | https://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE01825829 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1365
COPYRIGHT © 2021 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.