세종문화회관 소극장 리모델링 음향설계
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 전진용 | - |
| dc.contributor.author | 서춘기 | - |
| dc.contributor.author | 이평직 | - |
| dc.date.accessioned | 2022-07-16T19:22:44Z | - |
| dc.date.available | 2022-07-16T19:22:44Z | - |
| dc.date.issued | 2011-08 | - |
| dc.identifier.issn | 2733-6239 | - |
| dc.identifier.issn | 2733-6247 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/167784 | - |
| dc.description.abstract | The Little theater in Sejong Performing Arts Center is a proscenium theater with 447 seats, which was built in 1978. Acoustical remodeling design of the theater was carried out to improve the acoustic quality in audience area and to meet functional requirements of the theater. Design strategies included use of more reflective surfaces, installation of diffusers on sidewalls and orchestra pit, and side balconies. In particular, sidewall diffusers were designed through measurements of scattering coefficients according to ISO standardAfter remodeling, field measurements were performed to validate the acoustical design. The results was shown that unoccupied reverberation time varied from 0.93 to 1.06 s, and 1-IACC (Interaural Cross-correlation Coefficient) was more than 0.60. It was also found that sidewall diffusers resulted in decreases of COV (coefficient of variation)of early decay time and 1-IACC and increases of and Np (number of peak). Furthermore, the balance, refers to the sound power ratio of the stage and the pit sources, was -0.2 dB. | - |
| dc.format.extent | 8 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 대한건축학회 | - |
| dc.title | 세종문화회관 소극장 리모델링 음향설계 | - |
| dc.title.alternative | Acoustical Design for Remodeling the Little Theatre in Sejong Performing Arts Center | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.bibliographicCitation | 대한건축학회논문집, v.27, no.8, pp 313 - 320 | - |
| dc.citation.title | 대한건축학회논문집 | - |
| dc.citation.volume | 27 | - |
| dc.citation.number | 8 | - |
| dc.citation.startPage | 313 | - |
| dc.citation.endPage | 320 | - |
| dc.identifier.kciid | ART001584159 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | 음향설계 | - |
| dc.subject.keywordAuthor | 리모델링 | - |
| dc.subject.keywordAuthor | 세종문화회관 소극장 | - |
| dc.subject.keywordAuthor | 확산체 | - |
| dc.subject.keywordAuthor | 밸런스 | - |
| dc.subject.keywordAuthor | Acoustical Design | - |
| dc.subject.keywordAuthor | Remodeling | - |
| dc.subject.keywordAuthor | Little Theater in SPAC | - |
| dc.subject.keywordAuthor | Diffuser | - |
| dc.subject.keywordAuthor | Balance | - |
| dc.identifier.url | https://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE01676293 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.