Cited 0 time in
EXPERIMENTAL TEST OF DOUBLE-LAYER METHOD FOR INDUSTRIAL SPECT
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Park, Jang Guen | - |
| dc.contributor.author | Kim, Chan Hyeong | - |
| dc.contributor.author | Min, Chul Hee | - |
| dc.contributor.author | Jeong, Jong Hwi | - |
| dc.contributor.author | Kim, Jong Bum | - |
| dc.contributor.author | Moon, Jinho | - |
| dc.contributor.author | Jung, Sung-Hee | - |
| dc.date.accessioned | 2022-07-16T19:54:58Z | - |
| dc.date.available | 2022-07-16T19:54:58Z | - |
| dc.date.issued | 2011-07 | - |
| dc.identifier.issn | 0029-5450 | - |
| dc.identifier.issn | 1943-7471 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/168039 | - |
| dc.description.abstract | In industrial-type single-photon-emission computed tomography (SPECT) systems, the use of relatively large detectors and collimators for effective detection of high-energy gammas significantly limits imaging performance, primarily because of insufficient measurement points. In the present study, a simple but very effective image-quality improvement method, the double-layer method, was tested. In this method, two layers of identical SPECT systems are employed in order to increase the number of measurement points and, thereby, improve the image quality. For experimentation, the two identical detector layers were arranged for 30 deg of rotation with respect to each other. The results showed that the double-layer method indeed significantly improves the image quality of the industrial SPECT system, substantially reducing errors in source size and location for both low-energy ((99m)Tc) and high-energy ((113m)In) gamma sources. | - |
| dc.format.extent | 5 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | American Nuclear Society | - |
| dc.title | EXPERIMENTAL TEST OF DOUBLE-LAYER METHOD FOR INDUSTRIAL SPECT | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.13182/NT175-113 | - |
| dc.identifier.scopusid | 2-s2.0-79960686444 | - |
| dc.identifier.wosid | 000292169900020 | - |
| dc.identifier.bibliographicCitation | Nuclear Technology, v.175, no.1, pp 113 - 117 | - |
| dc.citation.title | Nuclear Technology | - |
| dc.citation.volume | 175 | - |
| dc.citation.number | 1 | - |
| dc.citation.startPage | 113 | - |
| dc.citation.endPage | 117 | - |
| dc.type.docType | Article; Proceedings Paper | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Nuclear Science & Technology | - |
| dc.relation.journalWebOfScienceCategory | Nuclear Science & Technology | - |
| dc.subject.keywordPlus | TOMOGRAPHY | - |
| dc.subject.keywordPlus | Computerized tomography | - |
| dc.subject.keywordPlus | Image quality | - |
| dc.subject.keywordPlus | Industrial emissions | - |
| dc.subject.keywordPlus | Particle beams | - |
| dc.subject.keywordPlus | Tomography | - |
| dc.subject.keywordAuthor | industrial gamma tomography | - |
| dc.subject.keywordAuthor | SPECT | - |
| dc.subject.keywordAuthor | multiphase flow system | - |
| dc.identifier.url | https://www.tandfonline.com/doi/abs/10.13182/NT175-113 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.