Cited 0 time in
A comparison of the Glidescope^Ⓡ to the McGrath^Ⓡ videolaryngoscope in patients
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Jeon, Woo Jae | - |
| dc.contributor.author | Kim, Kyoung Hun | - |
| dc.contributor.author | Yeom, Jong Hoon | - |
| dc.contributor.author | Bang, Mi Rang | - |
| dc.contributor.author | Hong, Jin-Bum | - |
| dc.contributor.author | Cho, Sang Yun | - |
| dc.date.accessioned | 2022-07-16T20:01:58Z | - |
| dc.date.available | 2022-07-16T20:01:58Z | - |
| dc.date.issued | 2011-07 | - |
| dc.identifier.issn | 2005-6419 | - |
| dc.identifier.issn | 2005-7563 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/168110 | - |
| dc.description.abstract | Background: The Glidescope^Ⓡ videolaryngoscope is a new device for tracheal intubation that provides an improved view of the larynx. This study was performed to compare the Glidescope with the McGrath videolaryngoscope in terms of time to intubation (TTI) and number of attempts. Methods: Patients were randomly allocated to one of two groups, Glidescope or McGrath group, by using computergenerated numbers. Tracheal intubation was attempted by an anesthesiologist with extensive experience using these two devices. The operator recorded ease of visualization of glottic structures based on the classification described by Cormack and Lehane. Number of failures, number of attempts and their duration, total intubation time, and events during the whole procedure were recorded. The duration of one attempt was defined as the time elapsed between picking up the endotracheal tube and verification of tracheal intubation with visualization of three expiratory carbon dioxide waveforms. TTI was defined as the sum of the duration of all intubation attempts (as many as three),excluding preoxygenation procedures. Results: TTI was significantly shorter for the Glidescope^Ⓡ compared to the McGrath^Ⓡ laryngoscope (40.5 vs. 53.3 s,respectively, P < 0.05). However, glottic views obtained at intubation were similar between the two groups. Number of intubation attempts was not significantly different between the two groups (1.03 ± 0.19 vs 1.10 ± 0.32, respectively)(mean ± SD). Conclusions: Study results demonstrated that the Glidescope reduced total intubation time in comparison with the McGrath, in terms of TTI in patients with normal airways. | - |
| dc.format.extent | 5 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | 대한마취통증의학회 | - |
| dc.title | A comparison of the Glidescope^Ⓡ to the McGrath^Ⓡ videolaryngoscope in patients | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.4097/kjae.2011.61.1.19 | - |
| dc.identifier.scopusid | 2-s2.0-80051717756 | - |
| dc.identifier.bibliographicCitation | Korean Journal of Anesthesiology, v.61, no.1, pp 19 - 23 | - |
| dc.citation.title | Korean Journal of Anesthesiology | - |
| dc.citation.volume | 61 | - |
| dc.citation.number | 1 | - |
| dc.citation.startPage | 19 | - |
| dc.citation.endPage | 23 | - |
| dc.identifier.kciid | ART001573011 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordPlus | adult | - |
| dc.subject.keywordPlus | anesthesist | - |
| dc.subject.keywordPlus | article | - |
| dc.subject.keywordPlus | comparative study | - |
| dc.subject.keywordPlus | device | - |
| dc.subject.keywordPlus | endotracheal intubation | - |
| dc.subject.keywordPlus | female | - |
| dc.subject.keywordPlus | human | - |
| dc.subject.keywordPlus | laryngoscope | - |
| dc.subject.keywordPlus | major clinical study | - |
| dc.subject.keywordPlus | male | - |
| dc.subject.keywordPlus | outcome assessment | - |
| dc.subject.keywordPlus | time | - |
| dc.subject.keywordPlus | time to intubation | - |
| dc.subject.keywordPlus | videolaryngoscope | - |
| dc.subject.keywordPlus | videorecording | - |
| dc.subject.keywordAuthor | Glidescope | - |
| dc.subject.keywordAuthor | McGrath Videolaryngoscope. | - |
| dc.identifier.url | https://scienceon.kisti.re.kr/srch/selectPORSrchArticle.do?cn=NART74422499&SITE=CLICK | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
